75W Single Output with PFC Function
HRP-75 series
Features :
Universal AC input / Full range
Built-in active PFC function
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Protections: Over temperature (optional)
Cooling by free air convection
1U low profile 38mm
Built-in remote ON-OFF control
No load power consumption<0.5W
All using 105 long life electrolytic capacitors
5 years warranty
SPECIFICATION
MODEL
HRP-75-3.3
HRP-75-5
HRP-75-7.5
HRP-75-12
HRP-75-15
HRP-75-24
HRP-75-36
HRP-75-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
15A
15A
10A
6.3A
5A
3.2A
2.1A
1.6A
0 ~ 15A
49.5W
0 ~ 15A
75W
0 ~ 10A
75W
0 ~ 6.3A
75.6W
120mVp-p
11 ~ 13.8V
1.5%
0 ~ 5A
75W
0 ~ 3.2A
76.8W
150mVp-p
0 ~ 2.1A
75.6W
200mVp-p
0 ~ 1.6A
76.8W
240mVp-p
45 ~ 55.2V
1.5%
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.5%
80mVp-p
4.7 ~ 5.8V
2.5%
100mVp-p
7.1 ~ 9V
2.5%
150mVp-p
14.2 ~ 18V
1.5%
OUTPUT
3.1 ~ 3.8V
21.6 ~ 28.8V 32 ~ 39.6V
1.5%
0.2%
0.5%
1.5%
0.2%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
2.0%
1.0%
1.0%
0.3%
0.3%
0.2%
2.0%
1.5%
1.0%
0.5%
0.5%
1800ms, 25ms/230VAC
1800ms, 25ms/115VAC at full load
20ms/115VAC at full load
120 ~ 370VDC
50ms/230VAC
Note.5 85 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.9/230VAC
77%
PF>0.95/115VAC at full load
82.5% 84% 87%
INPUT
88%
88.5%
89%
89%
1.2A/115VAC
0.7A/230VAC
65A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
35A/115VAC
<1mA / 240VAC
105 ~ 135% rated output power
OVERLOAD
Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed
6 ~ 7V
Protection type : Shut down o/p voltage, re-power on to recover
85 for 3.3V~15V; 80 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional)
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
41.4 ~ 48.6V 57.6 ~ 67.2V
3.96 ~ 4.62V
PROTECTION OVER VOLTAGE
5
5
OVER TEMPERATURE (OPTIONAL)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
FUNCTION
REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
394.8K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
129*98*38mm (L*W*H)
0.47Kg; 30pcs/ 15Kg/ 0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-75-SPEC 2009-10-09