APPLICABLE STANDARD
OPERATING
-25 C TO +85 C
-10
C TO +60 C
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
AC 100 V , DC 140 V
2 A
CURRENT
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
X
X
X
X
MARKING CONFIRMED VISUALLY.
ELECTRIC CHARACTERISTICS
20 m MAX.
1000 M MIN.
CONTACT RESISTANCE
CONTACT SHALL BE MEASURED AT DC 1 A
X
X
X
X
X
X
INSULATION RESISTANCE
100 V DC.
VOLTAGE PROOF
300 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
20 N MIN.
MECHANICAL CHARACTERISTICS
CONTACT RETENSION
-
APPLYING A PULL FORCE THE WIRE AFTER THE
X
X
FORCE
APPLICABLE CRIMPED CONTACT IS ASSEMBLED
WITH THE BODY.
CONNECTOR INSERTION MEASURED BY APPLICABLE CONNECTOR.
AND WITHDRAWAL FORCES
INSERTION AND WITHDRAWAL FORCES
-
LOCKING DEVICE WITH UNLOCK :70N MAX.
CONTACT RESISTANCE: 20
m MAX.
MECHANICAL OPERATION
VIBRATION
100 TIMES INSERTIONS AND EXTRACTIONS.
X
X
-
-
①NO ELECTRICAL DISCONTINUITY OF 10s.
FREQUENCY: 10 TO 500 (Hz),SINGLE
AMPLITUDE 0.75 mm, 98 m/s2 DIRECTIONS AT ②NO DAMAGE, CRACK AND LOOSENESS, OF
2 h, FOR 3 DIRECTIONS.
490 m/s2 DIRECTIONS OF PULSE 11 ms AT 3
PARTS.
①NO ELECTRICAL DISCONTINUITY OF10s.
②NO DAMAGE, CRACK AND LOOSENESS, OF
PARTS.
SHOCK
TIMES FOR 6 DIRECTIONS.
X
X
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
①INSULATION RESISTANCE: 5 MΩ MIN
(STEADY STATE)
(AT HIGH HUMIDITY).
②INSULATION RESISTANCE: 50 MΩ MIN
(AT DRY).
③NO DAMAGE.CRACK AND LOOSENESS OF
PARTS.
TEMPERATURE -55→ R/T(1) → +85 → R/T ℃ ①INSULATION RESISTANCE: 1000 MΩMIN.
RAPID CHANGE OF
TEMPERATURE
X
X
-
-
TIME 30 → 10 TO 15 → 30 → 10 TO 15 min ②NO DAMAGE.CRACK AND LOOSENESS OF
UNDER 5 CYCLES.
PARTS.
EXPOSED IN 5 SALT WATER SPRAY FOR
48h.
CORROSION SALT MIST
NO HEAVY CORROSIN RUIN THE FUNCTION.
DRY HEAT
COLD
EXPOSED AT + 85 ℃ , 96 h.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS
NO DAMAGE,CRACK AND LOOSENESS OF PARTS
NO WATER PENETRATION INSIDE CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR.
X
X
X
X
-
-
-
-
EXPOSED AT - 55 ℃ , 96 h.
SEALING
EXPOSED AT A DEPTH OF 1.8 m FOR 48 h.
AIRTIGHTNESS
APPLY AIR PRESSURE 40 kPa FOR 30 s TO
INSIDE CONNECTOR.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
REMARK
APPROVED
CHECKED
HY.KOBAYASHI
HY.KOBAYASHI
18.02.22
18.02.22
NOTE 1. (1)R/T:ROOM TEMPERATURE.
2. ABOVE SPECIFICATIONS SHOWS THE VALVE IN ASSEMBLED CONDITION WITH
APPLICABLE CRAMP CONTACT.
DESIGNED
HY.KISHI
18.02.21
3. SEALING AND AIRTIGHTNESS (AND OIL RESISTING)SHALL BE TESTED
UNDER MATED CONDITION WITH AN APPLICABLE CONNECTOR.
Unless otherwise specified, refer to IEC 60512(JIS C 5402).
DRAWN
MK.INOUE
18.02.06
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
ELC-116688-31-00
HR22-12WTLP-20PC(31)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CODE NO.
CL122-0064-9-31
FORM HD0011-2-1