APPLICABLE STANDARD
Operating
Storage Temperature
Range
-15C to +60C
-10C to +60C
(φ4.8)
Temperature Range
AC 100 V, DC 140 V
2 A
Rating
Voltage
Current
Applicable Cable
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
Contact Resistance
Measured at DC 1A.
30 m MAX. (Contact)
60 m MAX. (Ground)
200 M MIN.
Insulation Resistance
Voltage Proof
Measured at 250 V DC.
X
X
X
X
300 V AC applied for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Connector Insertion and
Withdrawal Forces
Measured with an applicable connector.
Insertion and withdrawal forces : 5 to 50 N.
X
X
-
-
50 m MAX. (Contact)
Mechanical Operation
Vibration
Mated and unmated 1000 times.
70 m MAX. (Ground)
Frequency: 10 Hz to 55 to 10 Hz every cycle ,5 min./cycle.
Single amplitude: 0.75 mm
1) No electrical discontinuity of more than 10 s.
X
-
2) No damage, cracks or looseness of parts.
Performed over 10 cycles in each of three mutually
perpendicular directions.
Shock
Acceleration: 490 m/s2, Half sine wave pulses of 11 ms.
1) No electrical discontinuity of more than 10 s.
Performed 3 times in each of three mutually perpendicular
directions.
2) No damage, cracks or looseness of parts.
X
X
-
-
ENVIRONMENTAL CHARACTERISTICS
1) Insulation resistance: 2 M MIN. (When high
humidity)
Damp Heat, Steady State
Subjected to a temperature of +40C, at a humidity of 90 to
95% for 96 hours.
2) Insulation resistance: 20 M MIN. (When dry)
3) No damage, cracks or looseness of parts.
Rapid Change of Temperature Temperature: -15 → R/T(1) → +60 → R/T C
1) Insulation resistance: 200 M MIN.
X
X
-
-
2) No damage, cracks or looseness of parts.
Time:
30 → 10 to 15 → 30 → 10 to 15 min
for 5 cycles.
Subjected to 5% salt spray for 48 hours.
No heavy corrosion which impairs functionality.
No damage, cracks or looseness of parts.
Corrosion Salt Mist
Dry Heat
Subjected to +60℃ for 96 hours.
X
X
-
-
-
Cold
Subjected to -15℃ for 96 hours.
No damage, cracks or looseness of parts.
Resistance to soldering heat
Soldering iron is placed to the soldering surface for
3 s. (Iron tip temperature +260℃)
No deformation or excessive looseness of
terminals.
X
X
Solder ability
Soldered at solder temperature, +260℃ for immersion
duration, 2 to 3 s.
Soldering surface shall be free from pin-holes,
de-wetted and un-wetted areas and other efects.
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
Remark
Note (1) R/T:Room Temperature
APPROVED
CHECKED
DESIGNED
TY.SUZUKI
TY.SUZUKI
20200925
20200925
DRAWN
Unless otherwise specified, refer to IEC 60512. (JIS C 5402)
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-043932-43-00
HR212-10P-8P(43)
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
CL0112-4001-3-43
FORM HD0011-2-1