Standard Model
Size : 4/3AU
HR-4/3AU
Data sheet
Dimensions
Capacity
Nominal1)
4000 mAh
3600 mAh
Minimum1)
1)Single cell capacity under the following condition.
Charge : 360 mA × 16 hours, Discharge : 720 mA(E.V.=1.00 V) at 20 °C
+0
17.0
−0.5
mm
General Specifications
Nominal Voltage
1.2 V
1.00 V
End Voltage
Charging Current x Time
Charge
3000 mA x about 1.4 hours
0 °C ~ +40 °C
0 °C ~ +50 °C
45 % ~ 85 %
Fast Charge 2)
Fast Charge 2)
Recommended
+0
67.5
−1.0
mm
Condition3)
Ambient Temp.
Discharge
Condition3)
Relative Humidity 4)
2)Use recommended charging system.
3)Charge or discharge on outside the recommended temperature range may
generate the battery degradation.
4)No water condensation.
Storage Conditions
Diameter
Height
17.0 +0/ -0.5 mm
67.5 +0/ -1.0 mm
53 g
Less than 30 days
Less than 90 days
Less than 1 year
-20 °C ~ +50 °C
-20 °C ~ +40 °C
-20 °C ~ +30 °C
45 % ~ 85 %
Dimensions
(including tube)
Ambient Temp.
Approx. Weight
(including tube)
Approx. Internal Impedance
Relative Humidity 6)
20 mΩ
at 1kHz 20゚C 5)
5) After 3 cycles of charge and discharge under the
conditions of 1), followed by the measurement 1~4
hours later.
6)No water condensation.
Nominal Charge Characteristics
Nominal Discharge Characteristics
1.8
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
Charge : 3000mA (-ΔV=10mV)
Rest : 3hours
Discharge : 3600mA (E.V.=1.00V)
1.7
40゚C
0゚C
25゚C
Ambient Temp. : 0, 25, 40゚C
1.6
1.5
1.4
1.3
1.2
1.1
1.0
40゚C
25゚C
0゚C
Charge : 3000mA(-ΔV=10mV)
Ambient Temp. : 0, 25, 40゚C
・Battery performance and lifespan are greatly affected by usage and temperature conditions.
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0
500
1000 1500 2000 2500 3000 3500 4000
・Test results vary depending on individual batteries.
Charge Time (hours)
Discharge Capacity (mAh)
・Single cell performance and lifespan are greatly affected by usage and temperature conditions.
・Test results vary depending on individual cells.
・Each values included in this material are intended to describe performance. They are not guaranteed.
ZFH