HO 40 .. 150-NP series
Absolute maximum ratings
Parameter
Supply voltage (not destructive)
Symbol
Unit
V
Value
8
UC
UC
TB
Supply voltage (not entering non standard modes)
V
6.5
°C
120
Primary conductor temperature
ESD rating, Human Body Model (HBM)
UESD
kV
2
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may
degrade reliability.
Insulation coordination
Parameter
Symbol
Unit
Value
Comment
Rms voltage for AC insulation test 50/60Hz/1 min
Ud
kV
4.3
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction rms voltage @ 10 pC
Clearance (pri. - sec.)
ÛW
Ue
kV
V
8
>930
>8
Primary / Secondary
dCI
dCp
mm
mm
Shortest distance through air
Shortest path along device body
Creepage distance (pri. - sec.)
>8
When mounted on PCB with
recommended layout
Clearance (pri. - sec.)
mm
>8
V0 according to
Case material
UL 94
Comparative tracking index
CTI
-
-
600
Reinforced insulation, non
uniform field according to
EN 50178, EN 61010
600 V
Application example
Application example
Application example
-
CAT III PD2
Based insulation, non uniform
field according to
EN 50178, EN 61010
1000 V
CAT III PD2
-
-
-
-
Simple insulation, non uniform
field according to
UL 508
600 V
CAT III PD2
Environmental and mechanical characteristics
Parameter
Symbol
Unit
°C
Min
-40
Typ
Max
105
Comment
Ambient operating temperature
TA
TS
m
Ambient storage temperature
°C
-40
105
Mass
g
31
Page 2/12
25July2014/Version 1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice