Fuseholders for Indicating Fuses
GMT Type
Dimensional Data
Printed Circuit Board Application
Shown With GMT Fuse Installed
Note: Similar Body Dimensions
of All Holders Are Identical.
0.31" Approx.
0.84"
(7.7mm)
(21.4mm)
0.84"
(21.4mm)
0.64"
(16.3mm)
1.02"
(25.9mm)
0.64"
(16.3mm)
0.13"
(3.2mm)
1.02"
HLT
(25.9mm)
0.15"
(3.8mm)
HLS
HLS-F
HLS-C
0.25"
0.15"
(6.4mm)
(3.8mm)
0.13"
(3.2mm)
HLT-F
0.08"
0.41"
(2.0mm)
(10.3mm)
0.25"
(6.4mm)
0.84"
(21.3mm)
HLT-D
Wire Wrap Terminal
0.64"
0.025" x 0.063"
CATALOG SYMBOL: HLS, HLT, PCT
FUSEHOLDERS FOR GMT TYPE INDICATING FUSES
ELECTRICAL RATING–60V DC, 125V AC
UL RECOGNIZED (GUIDE # IZLT2, FILE E14853)
15AMP (60V DC)
(16.3mm)
(0.64mm)
(1.6mm)
0.45"
(11.4mm)
Fuse Terminal
Alarm Terminal
PCT-A
PCT
0.11"
(2.8mm)
0.19"
Materials:
(4.8mm)
Body:
Thermosplastic, UL 94V0 flammability rating
Tin-plated bifrucated copper
0.25"
Terminals:
x "A" Spaces
(6.4mm)
Panel Mounting Data
Tolerance to be non-accumulative
0.15"(3.8mm) Dia.
0.16"(3.9mm) Dia.
For use with GMT Type Indicating Fuses
.041"
(10.4mm)
0.86"
(21.8mm)
"
0.27
(6.7mm)
1.21"
Multiple Fuseholders with bus bars
Ordering Information–Catalog No.
(30.8mm)
0.25"
(6.4mm)
.09" Dia. Holes
(2.4mm) (3 Holes Per Poles of Fuseholder)
Termination Location
Body Style
HLT
HLS (No flanges)
L
R
B
(Left only)
(Right only)
(Both ends)
No. of Poles 01 thru 25
(Min. of 2 poles required for bus bars)
Bus Bar Position
Type of bus bars used
B1*, B2, B3,
P1†
(Inside–
Both Sides)
P2
P3
P4
B4, B5, SL** (Short Leads .135")
ML** (Medium Leads .250")
** Not available with bus bars
(Outside–
Both Sides)
(Outside–
(Outside–
Left Only)
Right Only)
B2
B1
B3
B4
B5
("L" Bar Only)
(Angle Bar Only)*
("U" Bar Only)
(Angle & "L" Bars)
("L" &"U" Bars)
* Angle Bar mounts on common or center terminals only.
†Minimum of 4 Poles Required.
**SL Version is not available with bus bars.
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled.This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select-
ed, it should be tested by the user in all possible applications.
0712 BU-SB12567
Page 1 of 1
Data Sheet 5010