1.27mm Pitch Two-Piece Connector
HIF6 Series
Connector in combination with the HIF6 series connection type
ꢀHIF3B Series
ꢀHIF2 Series
(Board direct mount type)
(MIL-C-83503)
2
1
ꢀHIF5 Series
(Card edge type)
ꢀFeatures
1. Product Variation
The connection method is available with the board to
board type and insulation displacement type.
2. Broad applications
ꢀRC Series
(Micro ribbon connector)
ꢀFD Series
HIF2E, HIF3B and HIF5 can be combined one other,
because the 1.27mm pitch flat cable is used.
(D sub-ribbon connector)
3. Applicable Cables
The applicable cable is a (UL2651) AWG #28 flat cable
(7cores: 0.127mm, outer jacket diameter: 0.8 to1.0mm)
4. Mis-insertion Preventive Structure
The mis-insertion preventive guide prevents mis-
insertion.
Photo1 (For further information, refer to catalog page A133.)
ꢀApplications
Computers, peripheral and terminal equipment, PPC, various kinds of electronic equipment, Office Automation machines
ꢀProduct Specifications
Current rating: 0.5A
Operating Temperature Range: -55 to +85 ç (Note 1) Storage Temperature Range: -10 to +60ç (Note 2)
Rating
Voltage rating: 125V AC
Operating Humidity Range: 40 to 80%
Operating Humidity Range: 40 to 70% (Note 2)
Item
Specification
Condition
1.Insulation Resistance
2.Withstanding Voltage
3.Contact Resistance
4.Vibration
250V DC
1000M ohms min.
300V AC/1 minute.
No flashover or insulation breakdown.
30m ohms max.
0.1A
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions.
96 hours at temperature of 40ç and humidity of 90% to 95%
No electrical discontinuity of 1µs or more
Insulation resistance: 1000M ohms min.
5.Humidity (Steady state)
(-65ç: 30 minutesꢀ15 to 35ç: 5 minutes max.ꢀ
125ç: 30 minutesꢀ15 to 35ç: 5 minutes max.) 5 cycles
6.Temperature Cycle
No damage, cracks, or parts looseness.
Contact resistance: 30m ohms max.
7.Durability (Mating/un-mating)
8.Resistance to Soldering heat
500 cycles
Flow: 260ç for 10 seconds
No deformation of components affecting performance.
Manual soldering: 300ç for 3 seconds
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers non conducting condition of installed connectors in storage, shipment or during transportation.
A116