HER1G THRU HER7G
MINIATURE HIGH EFFICIENCY GLASS PASSIVATED RECTIFIER
Reverse Voltage -
50 to 1000 Volts
Forward Current -
1.0 Ampere
Features
Plastic package has Underwriters Laboratory
Flammability Classification 94V-0 utilizing
Flame retardant epoxy molding compound
Glass passivated junction in A-405 package
1.0 ampere operation at TA=55 with no thermal runway
Ultra fast switching for high efficiency
Mechanical Data
DIMENSIONS
Case: Molded plastic, A-405
Terminals: Axial leads, solderable per
MIL-STD-202, method 208
Polarity: Band denotes cathode
Mounting Position: Any
inches
mm
DIM
Note
Max.
Min.
Max.
0.205
0.106
0.024
-
Min.
4.2
A
B
C
D
0.165
0.079
0.020
1.000
5.2
2.7
0.6
-
2.0
0.5
Weight: 0.008 ounce, 0.235 gram
25.40
Maximum Ratings and Electrical Characteristics
Ratings at 25 ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
HER
1G
HER
HER
3G
HER
4G
HER
5G
HER
HER
Units
7G
Symbols
2G
100
70
6G
Peak reverse voltage, Repetitive;
Maximum RMS voltage
DC reverse voltage
VRM
VRMS
VDC
50
35
50
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
Volts
Volts
Volts
100
1000
Average forward current, IO@TA=55
3/8" lead length, 60Hz, resistive or inductive load
I(AV)
1.0
Amp
Peak forward surge current, IFM (surge)
8.3mS single half sine-wave superimposed
on rated load (MIL-STD-750D 4066 method)
IFSM
30.0
1.30
Amps
Maximum forward voltage @1.0A, 25
VF
IR
1.00
1.70
75
Volts
A
Maximum reverse current, @ Rated Tj=25
10.0
400.0
reverse voltage
Tj=100
Reverse recovery time (Note 1)
Typical junction capacitance (Note 2)
Typical thermal resistance (Note 3)
Trr
CJ
50
nS
F
17.0
60.0
R
/W
JA
Operating and storage temperature range
TJ, TSTG
-55 to +150
Notes:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0MHz and applied reverse voltage of 4.0 VDC
(3) Thermal resistance from junction to ambient and from junction to lead length 0.375 (9.5mm) P.C.B. mounted