HER151
THRU
DC COMPONENTS CO., LTD.
RECTIFIER SPECIALISTS
R
HER158
TECHNICAL SPECIFICATIONS OF HIGH EFFICIENCY RECTIFIER
VOLTAGE RANGE - 50 to 1000 Volts
CURRENT - 1.5 Amperes
FEATURES
* Low power loss, high efficiency
* Low leakage
* Low forward voltage drop
* High current capability
* High speed switching
* High surge capability
* High reliability
DO-15
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Lead: MIL-STD-202E, Method 208 guaranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any
* Weight: 0.4 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
HER151 HER152 HER153 HER154 HER155 HER156 HER157 HER158
SYMBOL
UNITS
Volts
Maximum Recurrent Peak Reverse Voltage
50
100
200
300
400
600
800
1000
V
V
RRM
RMS
Maximum RMS Voltage
35
50
70
140
200
210
300
280
400
420
600
560
800
700
Volts
100
1000
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
V
DC
Volts
I
O
1.5
Amps
at TA
= 50oC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC Method)
I
FSM
60
1.3
5.0
Amps
Volts
Maximum Instantaneous Forward Voltage at 1.5A DC
Maximum DC Reverse Current
VF
1.0
1.7
uAmps
at Rated DC Blocking Voltage T
A
= 25oC
I
R
Maximum Full Load Reverse Current
Average, Full Cycle .375*(9.5mm) lead length at T
100
uAmps
L
= 55oC
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
trr
75
20
nSec
pF
50
30
CJ
0C
T
J, TSTG
-65 to + 150
Operating and Storage Temperature Range
NOTES : 1. Test Conditions: I
F
= 0.5A, I
R = 1.0A, IRR = 0.25A
2. Measured at 1 MH
Z
and applied reverse voltage of 4.0 volts
62