H HiTRON
HARMONIC CORRECTION (PFC) AC/DC EXTERNAL DESKTOP
ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 100 WATTS
GREEN POWER SWITCHING POWER SUPPLIES HEPG98 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT
DESKTOP IEC320-3PL/2P AC RECEPTACLE
GREEN POWER
MEET IEC61000-3-2 HARMONIC CORRECTION
EMI MEET EN55022/FCC CLASS B
MEET UNIVERSAL SAFETY STANDARDS
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 100 Watts.
Output Connector: Optional.
Line Regulation: 0.2 % typical.
Input Voltage: 90-264Vac typical.
Power Factor Correction (PFC) installed.
Input Connector: IEC320-3PL/2P AC receptacle.
Input Frequency: 50/60Hz.
Inrush Current: Typ. 10.6Arms @230Vac 50Hz.
Input Current: 0.97A@115Vac/0.5A@230Vac
Dielectric Withstand: Meet IEC60950-1.
EMI: Meet EN55022/FCC Class B.
Load Regulation: ± 2.5% typical.
Noise & Ripple: 1% typical peak to peak.
OVP: Built-in. (Latch)
Over Temp. Protection (OTP): Installed.
Overload Protection (OLP):
Hold-up Time: 15mS @115Vac/ 28mS@230Vac typical.
Green Power: 0.29W @ 132Vac/ 0.45W @264Vac.
Earth Leakage: Less than 0.24mA.
Fully protected against output overload and short circuit.
OLP set at about 110-135% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 88-90% typical.
Operating Temperature: 0 to +25/35/40°C
without derating. (various with output voltage)
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04%/°C typical.
Cooling: Free air convection.
Switching Frequency: 25-65 KHz.
Circuit Topology: Fixed Flyback Circuit.
Transient Response: Output voltage returns in less than
1mS following a 25% load change.
Safety Standard: Meet UL60950-1/EN60950-1 Class I or II.
Harmonic Current Emission, EN61000-3-2 compliance.
Power Density: 5.3 Watts/Cubic inch.
Construction: Impact resistant plastic enclosure case.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The typical cord length is about 1 meter (3.3 ft.), AWG#18 cord for various load conditions.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
For the details of safety approval, please consult the factory.
-41-