REVISION AC
HCSD-XX-X-XX.XX-01-XXX-XXX
XX.XX (SEE NOTE 10)
OPTION #2
No OF POSITIONS
DO NOT
SCALE FROM
THIS PRINT
(SEE FIG 3 THRU FIG 19
-02 THRU -36
FOR AVAILABLE OPTIONS)
(STANDARD COLOR
CODED CABLE)
OPTION #1
(SEE FIG 3 THRU FIG 19 FOR
AVAILABLE OPTIONS)
(-32 & -36 ONLY AVAILABLE
WITH -G OPTION)
LEAD STYLE
(POSITIONS 21-36: EXISTING
CUSTOMERS ONLY)
CB-XX-28-7/36-050-G
ASSEMBLY LENGTH
(2 INCH MINIMUM)
END ASSEMBLY
-S: SINGLE END
-D: DOUBLE END
FIG 3
-G: GRAY CABLE
(DIFFERENT AS SHOWN, OTHERWISE
SAME AS FIG1)
FIG 2
-T: BRIGHT ACID TIN ON ENTIRE PIN
(USE HCSD-XX-01-TX)
LEAVE BLANK FOR 10µ" SELECTIVE GOLD IN
CONTACT AREA, BRIGHT ACID TIN ON TAIL.
HCSD-08-S-XX.XX-01 SHOWN
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG1)
C
FIG 4
-T: TIN PLATING
XX.XX (SEE NOTE 10)
.200 5.08 REF
01
02
(NO OF POS x .100[2.54] + .180[4.57] REF
.150 3.81 REF
HCSD-XX-01-N
BROWN OR RED WIRE
INDICATES POS #1
.010[0.25] MAX
CABLE OVERHANG
(TYP)
.050 1.27 REF
CB-XX-28-7/36-050-C
FIG 5
.375 9.53 REF
(SEE NOTE 5)
-N: NOTCH
(NOT AVAILABLE ON -02 POSITION)
(DIFFERENT AS SHOWN, OTHERWISE
SAME AS FIG1)
NOTCH DENOTES
FIRST POSITION
(SEE NOTE 8)
HCSD-XX-01-X
FIG 1
HCSD-08-D-XX.XX-01 SHOWN
NOTES:
F:\DWG\MISC\MKTG\HCSD-XX-X-XX.XX-01-XXX-XXX-MKT.SLDDRW
C
1.
REPRESENTS A CRITICAL DIMENSION.
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
2. HIDDEN LINES ARE USED TO SHOW POLARIZATION WHEN USING -N OPTION.
3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED FOR SHORTS AND OPENS
4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 1000V.
*
*
UNLESS OTHERWISE SPECIFIED,
C
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
5. HCSD-XX-01-X TO BE PRESSED TOGETHER WITH NO GAPS BETWEEN CABLE & BODIES.
DECIMALS
ANGLES
C 6. CONDUCTORS SHALL BE CONSISTENT IN APPEARANCE, SOLDER MUST MAINTAIN
CABLE STRANDS WITHIN THE MAX DIA. TOLERANCE.
.XX: .01 [.3]
1
520 PARK EAST BLVD, NEW ALBANY, IN 47150
.XXX: .005 [.13]
PHONE: 812-944-6733
FAX: 812-948-5047
code 55322
7. NOTE DELETED.
.XXXX: .0020 [.051]
e-Mail info@SAMTEC.com
8. FOR R OR RW OPTION, CABLE RIB ORIENTATION CAN BE EITHER TOWARDS OR AWAY
FROM THE CAP.
SHEET SCALE: 3:2
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
.100 CL MOLD TO POS DOUBLE
ROW FEMALE ASSEMBLY
9. WHEN CUTTING CABLE TO LENGTH, CONDUCTORS SHOULD NOT EXTEND PAST THE CABLE
INSULATION, EXTENDING LESS THAN 25% OF CABLE THICKNESS ON CONSECUTIVE AND LESS
THAN 50% OF THE CABLE THICKNESS ON NON-CONSECUTIVE STRANDS IS CONSIDERED A
PROCESS INDICATOR.
INSULATOR: LCP, UL 94 VO, COLOR: BLACK
CONTACT: PHOS BRONZE
CABLE: COLOR-CODED OR GRAY PVC/TIN PLATED COPPER
DWG. NO.
HCSD-XX-X-XX.XX-01-XXX-XXX
10. FOR LENGTHS LESS THAN 12.5", TOLERANCE SHALL BE ±.125[3.18], ALL OTHER LENGTHS SHALL BE ±1%.
BY:
KOLB
08/03/1990 SHEET 1 OF 4