ISOLATED DC/DC CONVERTERS
38 Vdc - 55 Vdc Input 53 Vdc/8 A Output
Aug. 10, 2011
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
HBW53V08xRG
RoHS Compliant
Rev.C
Fixed Frequency (270 kHz)
Output Over-Voltage Shutdown
Over Temperature Protection
Isolated
High Efficiency
Low Cost
SCP/OCP
Basic Insulation
Input Under/Over-Voltage
Lockout
Remote On/Off
Excellent Thermal Performance
Output Voltage Trim
Both of IEEE802.3af and
IEEE802.3at compliant
Class 2, Category 2, Isolated
DC/DC Converter (refer to
IPC-9592)
Description
The HBW53V08xRG is an isolated dc/dc converter that operates from a nominal 48 Vdc source. This unit
provides up to 424 W of output power from a nominal 48 Vdc input. This unit is designed to be highly efficient and
low cost. The converter is provided in an industry standard half brick package.
Part Selection
Output
Voltage
Input Voltage
Max. Output
Current
Max. Output
Power
Typical
Efficiency
Model Number
53 Vdc
53 Vdc
38 Vdc - 55 Vdc
38 Vdc - 55 Vdc
8 A
8 A
424 W
424 W
93%
93%
HBW53V08MRG
HBW53V08SRG
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Notes
Input Voltage
-0.3 V
-
65 V
Remote On/Off
-0.3 V
2250 V
-40 C
-55 C
-
-
-
-
5 V
-
I/O Isolation Voltage
Ambient Temperature
Storage Temperature
100 C
125 C
Input Specifications
Parameter
Input Voltage
Min
38 V
Typ
Max
55 V
Notes
48 V
70 mA
-
Input Current (no load)
-
-
-
100 mA
12.5 A
20 mA
Input Current (full load)
Remote Off Input Current
10 mA
Input Reflected Ripple Current
(pk-pk)
With simulated source impedance of 12
uH, 5 Hz to 20 MHz; use a 100uF/100 V
electrolytic capacitor with ESR = 1 ohm
max, at 200 kHz
-
-
20 mA
5 mA
40 mA
10 mA
Input Reflected Ripple Current
(rms)
Turn-on Voltage Threshold
Input Under Voltage Threshold
Input Over Voltage Threshold
34 V
33 V
56 V
36 V
35 V
-
37.5 V
36.5 V
60 V
Note: All specifications are typical at nominal input, full load at 25 C unless otherwise stated
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com