IPN = 4000..20000 A
Current Transducers HAZ 4000..20000-SB
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
VOUT= ± 10 V
Preliminary
Electrical data
Primarynominal
current
Primarycurrent
measuringrange
IP (A)
Type
IPN (A)
4000
6000
10000
12000
14000
20000
± 4000
± 6000
± 10000
± 12000
± 14000
± 20000
HAZ 4000-SB
HAZ 6000-SB
HAZ 10000-SB
HAZ 12000-SB
HAZ 14000-SB
HAZ 20000-SB
Features
· Hall effect measuring principle
· Galvanic isolation between primary
and secondary circuit
· Instantaneous voltage output
· Isolation voltage 12kV~
· Low power consumption
VC
IC
IOC
Vd
Supply voltage (± 5 %)
Current consumption
Overload capacity
R.m.s. voltage for AC isolation test, 60 Hz, 1 mn
R.m.s. rated voltage, safe separation
Isolation resistance @ 500 VDC
Output voltage @ ± IPN, RL = 10 kW, TA = 25°C
Output internal resistance
Load resistance
± 15
± 30
V
mA
At
kV
V
MW
V
W
30,000
12
20001)
> 1000
± 10
· Package in PBT meets UL 94-V0
Vb
RIS
VOUT
ROUT
RL
Advantages
approx. 100
· Easy mounting
> 10
kW
· Small size and space savings
· Only one design for wide current
ratings range
Accuracy - Dynamic performance data
X
Accuracy @ IPN, TA = 25°C (without offset)
Linearity 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
< ± 1
< ± 1 % of IPN
< ± 50
%
· High immunity against external
interference
e
VOLE
VOH
mV
< ± 50
< ± 1
< ± 0.05 %/K
< 10
> 50
mV
mV/K
Applications
VOT
TCe
tr
di/dt
f
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth 3)(- 3 dB)
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
· Power supplies for welding and
elecommunication applications.
G
ms
A/ms
kHz
DC .. 3
General data
TA
TS
m
Ambient operating temperature
- 25 .. + 80 °C
- 25 .. + 80 °C
Ambient storage temperature
Mass
approx. 6
kg
4)
Standards
EN 50178
45
Minimum creepage & clearance
m m
Housing PBT 30% glassfiber
CTI IIIa, UL94-V0
1)
Notes : Pollution class 2, overvoltage category III, reinforced insulation
2)
Linearity data exclude the electrical offset.
Please refer to derating curves in the technical file to avoid excessive
3)
core heating at high frequency
Please consult characterisation report for more technical details and
4)
040713/1
application advice.
LEM Components
www.lem.com