Panel Mount
Datasheet
HAC Series
• Load Voltage range 24 to 660 VAC
• Output rating up to 150 Arms
• Zero Voltage or Instantaneous Turn-on options
• AC or DC input control options
• Locking Input Connector
• Optional Transient Protection & installed Thermal Pad
PRODUCT SELECTION
Control Voltage
3-32 VDC
150 A
HAC24D150 ,HAC60D150
HAC24B150 ,HAC60B150
HAC24A150 ,HAC60A150
90-140 VAC
150-270 VAC
AVAILABLE OPTIONS
Control Voltage
A: 150-270 VAC
B: 90-140 VAC
D: 4-32 VDC
Overvoltage Protection
Blank: Not Included
P: Included (6)
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On (5)
Series
HAC
24
A
150
P
H
-10
Operating Voltage
24: 24-280 VAC
60: 48-660 VAC
Rated Load Current
150: 150 Amps
Thermal Pad
Blank: Not Included
H: Included
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS (1)
Description
HAC24x150
HAC60x150
Operating Voltage (47-63Hz) [Vrms]
24-280
48-660
Transient Overvoltage [Vpk]
600
1200
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µSec]
Maximum Load Current [Arms](2)
1
500
150
1
500
150
Minimum Load Current [Arms]
0.15
0.15
Maximum Surge Current [Apk] 1 Cycle 50/60 Hz
Maximum I²t for fusing (10msec)/(8.33msec)[A²sec]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
Thermal Resistance Juncti on to Case (Rjc) [°C/W]
Minimum Power Factor (with Maximum load)
Wire Size max (solid/stranded) [AWG/ IEC mm²] (3)
Output Terminal Nut Torque Range [in lb (Nm)
HP Rating UL 508/IEC60957 [HP (KW)]: 240 VAC
HP Rating UL 508/IEC60947 [HP (KW)]: 480 VAC
1670/1750
13950/12709
1.15
1670/1750
13950/12709
1.15
0.15
0.5
0.15
0.5
2/0 / 67.4
225-300 (25.4-33.9)
10 (7.5)
N/A
2/0 / 67.4
225-300 (25.4-33.9)
N/A
25 (18.75)
Do not forget to visit us at: www.crydom.com