COST SAVING
SUBMINIATURE
PC BOARD RELAYS
HA-RELAYS
14.0
.551
FEATURES
14.2
.559
26.5
1.043
26.3
1.035
• Compact construction
16.9
.665
• Sensitive - very low operating power
17.7
.697
• Soldering flux inflow prevented by molded construction
• Contact capacity - 3 A 250 V AC, 30 V DC
• Simple mechanism for stable quality - only 9 pieceparts
• Amber sealed types available
HAE Amber Relays
mm inch
SPECIFICATIONS
HA1 Standard type
Contacts
HA1E Amber sealed type
Contacts
Arrangement
1 Form C
Arrangement
1 Form C
Contact material
Silver-nickel
Contact material
Gold-clad over silver-nickel
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 mΩ
50 mΩ
Max. switching power
Rating
750 VA, 90 W
Max. switching power
Rating
500 VA, 90 W
250 V AC, 30 V DC
2 A AC, 3A DC
107
(resistive
load)
Max. switching voltage
Max. switching current
Mechanical
250 V AC, 30 V DC
(resistive
load)
Max. switching voltage
Max. switching current
Mechanical
3 A
107
105
Expected
life (min.
operations)
Expected
life (min.
operations)
3 A 250 V AC
Electrical
2 A 250 V AC
Electrical
105
2×105
3 A 30 V DC
5×105
3 A 30 V DC
(resistive)
(resistive)
Coil
Coil
Minimum operating power
Nominal operating power
(AC) 0.58 VA, (DC) 230 mW
(AC) 0.9 VA, (DC) 360 mW
Minimum operating power
Nominal operating power
(AC) 0.58 VA, (DC) 230 mW
(AC) 0.9 VA, (DC) 360 mW
Characteristics
Characteristics
Maximum operating speed
20 cpm
Maximum operating speed
20 cpm
Initial insulation resistance*1
(at 25°C, 50% R.H.)
Initial insulation resistance*1
(at 25°C, 50% R.H.)
Min. 100 MΩ at 500 V DC
Min. 100 MΩ at 500 V DC
Initial
breakdown
voltage*2
Initial
breakdown
voltage*2
Between open contacts
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Between open contacts
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Between contacts and coil
Between contacts and coil
Operate time*3 (at nominal voltage)
(at 20°C)
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Operate time*3 (at nominal voltage)
(at 20°C)
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Release time (without diode)*3
(at nominal voltage)(at 20°C)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
Release time (without diode)*3
(at nominal voltage)(at 20°C)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
Max. (AC) 60°C, (DC) 40°C
with nominal coil voltage and
at 3A switching current
Max. (AC) 60°C, (DC) 40°C
with nominal coil voltage and
at 3A switching current
Temperature rise (at 20°C)
Temperature rise (at 50°C)
Functional
Shock resistance
98 m/s2 {10G}
980 m/s2 {100G}
Functional
Shock resistance
98 m/s2 {10G}
980 m/s2 {100G}
Destructive
Destructive
10 to 55Hz
at double amplitude of 1mm
10 to 55Hz
at double amplitude of 1mm
Functional
Vibration resistance
Functional
Vibration resistance
10 to 55Hz
at switching of 2mm
10 to 55Hz
at double amplitude of 2mm
Destructive
Destructive
Conditions for operation,
transport and storage*4
(Not freezing and con-
densing at low tempera-
ture)
Conditions for operation,
transport and storage*4
(Not freezing and con-
densing at low tempera-
ture)
Ambient
temp.
–40°C to +50°C
–40°F to +122°F
Ambient
temp.
–40°C to +50°C
–40°F to +122°F
Humidity
5 to 85%R.H.
Humidity
5 to 85%R.H.
Unit weight
Approx. 15 g .53 oz
Unit weight
Approx. 15 g.53 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Intial breakdown voltage" section
*2 Detection current: 10 mA
*3 Excluding contact bounce time
*4 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
208