Panel Mount
Datasheet
H16WD Series
• Ratings from 25A to 90A @ 48-690 VAC
• 1600 Volts Blocking
• DC control
• Direct Bond Copper substrate
• EMC Compliant to Level 3
• Direct Power Lead Frame
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Epoxy Free Design
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage
4-32 Vdc
25A
H16WD6025
50A
H16WD6050
75A
H16WD6075
90A
H16WD6090
AVAILABLE OPTIONS
Rated Load Current
25: 25 Amps
50: 50 Amps
75: 75 Amps
90: 90 Amps
Input Status LED
Blank: Not Included
G: Included
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On
Transient Overvoltage
6WD: 1600 Vpk
Series
(3)
H1
6WD
60
25
K
G
H
-10
Operating Voltage
Termination
Thermal Pad
60: 48-690 VAC
Blank: Screw
F: Quick Connect (1)
(Up to 50 Amps models)
Blank: Not Included
H: Included
Required for valid part number
For options only and not required for valid part number
* Not all part number combinations are available.
Contact Crydom Technical Support for informacion on
the availability of a specific part number.
(2)
K: Hex standoffs
OUTPUT SPECIFICATIONS (4)
Description
Operating Voltage (47-440Hz) [Vrms]
Transient Overvoltage [Vpk]
Rated Load Current [Arms] (5)(2)
25A
48-690
1600
25
50A
48-690
1600
50
75A
48-690
1600
90A
48-690
1600
75
90
Rated Load Current {UL508 Motor Controller} [Arms] (5)
Minimum Load Current [mArms]
10
150
20
150
30
150
45
150
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum I²t for Fusing (50/60Hz) [A² sec]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
HP rating UL 508/IEC60947[HP (KW)]: 240 VAC
HP rating UL 508/IEC60947[HP (KW)]: 380 VAC
HP rating UL 508/IEC60947[HP (KW)]: 480 VAC
HP rating UL 508/IEC60947[HP (KW)]: 600 VAC
Minimum Power Factor (at Maximum Load)
1.0
500
239/250
285/259
0.8
1.0
500
597/625
1779/1621
0.45
1.0
500
954/1000
4555/4150
0.3
1.0
500
1145/1200
6560/5976
0.27
1.3
1.3
1.2
1.2
1.5 (1.1)
2 (1.5)
3 (2.2)
3 (2.2)
0.5
3 (2.2)
5 (3.7)
5 (3.7)
10 (7.4)
0.5
5 (3.7)
7.5 (5.6)
10 (7.4)
15 (11.2)
0.5
7.5 (5.6)
15 (11.2)
20 (14.9)
25 (18.6)
0.5
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.