5W AC-DC Single Output Wall-mounted type
GS05U-USB
Features :
Universal AC input / Full range
No load power consumption <0.3W
Compact size
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Pass LPS
100% full load burn-in test
Fully enclosed plastic case
Low cost, high reliability
2 years warranty
SPECIFICATION
ORDER NO.
GS05U-USB
SAFETY MODEL NO.
GUSB05
DC VOLTAGE
Note.2 5V
RATED CURRENT
CURRENT RANGE
RATED POWER
1.00A
0 ~ 1.00A
5W
OUTPUT
RIPPLE & NOISE (max.) Note.3 90mVp-p
VOLTAGE TOLERANCE Note.4 4.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 4.0%
SETUP, RISE, HOLD UP TIME 1500ms, 20ms, 15ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
Note.7 69%
INPUT
AC CURRENT
0.15A / 100VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
35A / 230VAC
0.25mA / 240VAC
105 ~ 135% rated output voltage power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 160% rated output voltage, detect on main control IC
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
U1 Tj 135 typically (U1) detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +50 (Refer to output load derating curve)
WORKING TEMP.
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA22.2 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
I/P-O/P:4242VDC
EMC
(Note. 8)
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC part 15 Class B
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
MTBF
1100Khrs min. MIL-HDBK-217F(25
41.86*32.76*23.8mm (L*W*H)
26g ; 300pcs / 10.3Kg / CARTON
USB Type A
)
OTHERS
DIMENSION
PACKING
PLUG
CONNECTOR
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 115VAC.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS05U-USB-SPEC 2011-03-31