12~15W AC-DC Single Output Desktop
GS15A series
Features :
Universal AC input / Full range
No load power consumption <0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
Approvals: UL / CUL / TUV / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
SPECIFICATION
ORDER NO.
GS15A-1P1J GS15A-11P1J GS15A-2P1J GS15A-3P1J GS15A-4P1J GS15A-5P1J GS15A-6P1J GS15A-8P1J
SAFETY MODEL NO.
GPSU15A-1
Note.2 5V
GPSU15A-1-1 GPSU15A-2
GPSU15A-3
12V
GPSU15A-4
15V
GPSU15A-5
18V
GPSU15A-6
24V
GPSU15A-8
48V
DC VOLTAGE
7.5V
9V
RATED CURRENT
CURRENT RANGE
RATED POWER
2.40A
1.60A
1.66A
0 ~1.66A
15W
1.25A
1.00A
0.83A
0.62A
0.31A
0 ~ 2.40A
12W
0 ~ 1.60A
12W
0 ~ 1.25A
15W
0 ~ 1.00A
15W
0 ~ 0.83A
15W
0 ~ 0.62A
15W
0 ~ 0.31A
15W
RIPPLE & NOISE (max.) Note.3 50mVp-p
80mVp-p
6 ~ 8V
80mVp-p
8 ~ 11V
80mVp-p
11 ~ 13V
100mVp-p
13 ~ 16V
120mVp-p
16 ~ 21V
150mVp-p
21 ~ 27V
240mVp-p
33 ~ 48V
OUTPUT
5 ~ 6V
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
0.5%
5.0%
5.0%
0.5%
5.0%
3.0%
0.5%
3.0%
3.0%
0.5%
3.0%
3.0%
0.5%
3.0%
2.0%
0.5%
2.0%
2.0%
0.5%
2.0%
LINE REGULATION
LOAD REGULATION
Note.5 0.5%
Note.6 5.0%
SETUP, RISE, HOLD UP TIME 3000ms, 50ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
Note.7 75%
78%
80%
80%
80%
81%
83%
85%
INPUT
AC CURRENT
0.5A / 100VAC
50A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
105 ~ 250% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
PROTECTION
OVER VOLTAGE
Protection type : Clamp by zener diode
0 ~ +50 (Refer to "Derating Curve")
WORKING TEMP.
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA22.2, EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
SAFETY &
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
EMC
(Note. 8)
500Khrs min. MIL-HDBK-217F(25
100*58.5*32.8mm (L*W*H)
)
OTHERS
DIMENSION
190g ; 90pcs / 18Kg / CARTON
PACKING
PLUG
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type center positive for stock ; Other type available by customer requested
Standard type 18Awg UL1185 6ft and 5ft for 3.3V output only for stock ; Other type available by customer requested
CONNECTOR
CABLE
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 230VAC.
8.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS15A-SPEC 2011-06-14