REVISION K
DESIGNED & DIMENSIONED
IN MILLIMETERS[INCHES]
GRFX-P-C-XX-XXXX-XXX-X-X-XX
PLATING
SERIES
BLANK: 30µ" GOLD CENTER CONTACT
3µ" GOLD OUTER CONTACT
-GF:10µ" GOLD CENTER CONTACT
3µ" GOLD OUTER CONTACT
100µ" NICKEL REMAING PARTS
(SEE SHT 2, TABLE 3)
GRF1-: GRF 50 OHM CONNECTORS
GRF7-: GRF 75 OHM CONNECTORS
(SEE SHT 2, TABLE 2)
DO NOT
SCALE FROM
THIS PRINT
GENDER
-P: PLUG
CABLE
-C: CABLE
(No OF POS x 5.00[.197]) + 11.60[.457]
SCREW OPTION
-S: CAPTIVE PANEL SCREWS
BLANK: NO SCREWS
END OPTION
-S: SINGLE (SEE NOTE 5)
-D: DOUBLE
No OF POSITIONS
-02,-04, -06, -08
Ø"A"
REF
C
LENGTH
-XXXX (IN MILLIMETERS)
0100 MIN (SEE NOTE 4)
TERMINATION
CABLE
8.89 .350
REF
-C1: USE CCA-316 COAX CABLE
-CA2: USE CCA-178 COAX CABLE
-CA3: USE CCA-179 COAX CABLE
-C12: USE TCF-3075F-01-COAX CABLE
-CS5: USE MWC-2550-01-COAX CABLE
(SEE SHT 2, TABLE 4)
*
*
*
28.58 1.125
REF
*NOT RELEASED FOR PRODUCTION.
C XXXX
CABLE LENGTH
(SEE TABLE 1 FOR TOLERANCE)
15.50 .610
REF
4.19 .165
REF
C
2.81±0.20 .111±.008
RFXXX-XXXXX-SING-XXXX
(SEE TABLE 2, 3, 4)
POLARIZATION KEY
1-64 THREAD
(No OF POS -1)
x 5.00[.197]
'A'
6.00 .236 REF
SUB-GRF1-XX-S
(No OF POS x 5.00[.197]) + 7.20[.283]
FIG 1
GRFX-P-C-04-XXXX-CXX-S-S-XX SHOWN
Ø "C" (PIN)
C
Ø "B" REF
(SHELL)
C
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN MILLIMETERS. THIS DOCUMENT CONTAINS INFORMATION
TOLERANCES ARE:
PROPRIETARY NOTE
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
DETAIL 'A'
NOTES:
DECIMALS
ANGLES
5 °
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
SCALE 6 : 1
.X: 0.3 [.01]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
C
1.
REPRESENTS A CRITICAL DIMENSION.
.XX: 0.13 [.005]
PHONE: 812-944-6733
FAX: 812-948-5047
code 55322
2. USE REMOVAL TOOL #CAT-EX-GRF1-01 TO REMOVE CABLES
FROM ASSEMBLY.
.XXX: 0.051 [.0020]
MATERIAL:
e-Mail info@SAMTEC.com
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
DESCRIPTION:
3. MINIMUM PULL OUT FORCE: 5 LBS.
COVERS: ABS
4. CABLE LENGTHS LONGER THAN 1000 MILLIMETERS ARE NOT
SUPPORTED BY S.I. TEST DATA.
RF GANGED CABLE JACK ASSEMBLY
DWG. NO.
PLUG: SHELL: BeCu, CONTACT: BRASS
CABLE; -C1: RG316
-CA2: RF178
5. SINGLE ENDED ASSEMBLIES BLUNT CUT/NON PREPPED ON CUT END.
6. ASSEMBLY TO BE 100% TESTED FOR OPENS & SHORTS.
7. ASSEMBLY TO BE 100% HI-POT TESTED PER TABLE 1,
-CA3: RG179
GRFX-P-C-XX-XXXX-XXX-X-X-XX
-C12: TCF-3075F-01-01
-CS5: MWC-2550-01
SHEET 1 OF 3
BY:
D PURVIS 9/15/2004
F:\DWG\MISC\MKTG\GRFX-P-C-XX-XXXX-XXX-X-X-XX-MKT.SLDDRW