描述
65 Watt Multiple Output Global Performance Switchers

GLM65E 数据手册

 浏览型号GLM65E的Datasheet PDF文件第2页 
GLC65 Commercial/GLM65 Medical  
65 Watt Multiple Output Global Performance Switchers  
MULTIPLE OUTPUT GLOBAL PERFORMANCE SWITCHERS  
Summary:  
• 65 Watt Wide Range Input  
• High Efficiency (Up to 90%)  
• Universal input 90-264 Vac  
• 2-year warranty  
• Also available in single outputs  
• Conducted EMI complies with FCC Class B and  
CISPR 22 Class B (Commercial models) and  
CISPR 11 Class B (Medical models)  
• Exempt from line harmonics standard EN61000-3-2  
• Commercial Approved to UL1950, CSA-C22.2 No. 950,  
• Medical Approved to UL2601-1, CSA 22.2 No. 601.1, and  
EN60601-1• Medical Approved to UL2601-1, CSA 22.2 No. 601.1,  
• RoHS Compliant (G suffix)  
marked to LVD  
SPECIFICATIONS  
Ac Input  
Minimum Load  
90-264 Vac, 47-63 Hz single phase.  
No minimum load required on any output. However, regulation limits may be  
exceeded if extreme conditions are applied. Contact factory for assistance.  
Output Power  
Total continuous output power is 60 W, 75 W peak for 60 s 10% duty cycle.  
Total continuous rating with 150 LFM of air is 70 W.  
Temperature Coefficient: 0.03%°C typical on all outputs.  
Voltage Adjustment  
Input Current  
Units provided with one potentiometer capable of adjusting all 3 outputs a mini-  
mum of +/- 5% from nominal setting.  
Units are exempt from input current harmonic requirements of EN61000-3-2  
when output power is less than 62W. Maximum input current at minimum  
input voltage and output overload will be less than 2.0 A.  
EMI / EMC Compliance:  
Inrush Current  
All models include built-in EMI filtering to meet EMC requirements of IEC601-1-2.  
Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over  
the first ac half-cycle under cold start conditions will not exceed 37 A.  
PERFORMANCE  
EMC STANDARD  
Input Protection  
Conducted Emissions GLC65  
Conducted Emissions GLM65  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
EN55022 Class B; FCC Class B  
EN55011 Class B; FCC Class B  
EN61000-4-2, Level 3  
EN61000-4-3, Level 3  
EN61000-4-4, Level 3  
EN61000-4-5, Level 3  
EN61000-4-6, 3V, 80%  
EN61000-4-11  
Internal AC fuse provided on all units. Designed to blow only if a catastrophic  
failure occurs in the unit -- Fuse does not blow on short circuit or unsustained  
overload.  
Holdup Time  
Surge Susceptibility  
Output voltage stays within regulation for 20 ms from loss of ac input at 65 W  
load, from 120 Vac input.  
Conducted RF Susceptibility  
Voltage Sags & Surges  
Line Frequency Harmonics  
Efficiency  
80% minimum.  
EN61000-3-2 Class A (>62Wout)  
Exempt (<62Wout)  
Overload Protection  
GLC65 Commercial - Safety  
Fully protected against short circuit and output overload. Short circuit  
protection is cycling type power limit and will automatically recover after  
removal of fault.  
SL Power Electronics Corp declares under our sole responsibility that all models  
are in conformity with the applicable requirements of EN60950 following the  
provisions of the Low Voltage Directive 73/23/EEC. All models are approved to  
UL1950 (with no D3 deviations), CSA22.2 No. 950-95 3rd edition, Level 3, IEC950,  
EN60950. CB certificate available.  
Overvoltage Protection  
Built in with firing point set. OVP firing reduces output to less than 50% of  
nominal voltage in less than 50 ms.  
Commercial Leakage Current  
Less then 500 μA @ 120 Vac. Less then 1.2 mA @ 240 Vac.  
Output Noise  
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with  
scope probe directly across output terminals of the power supply with load  
terminated with 1μF capacitor.  
GLM65 Medical - Safety  
Approvals: All models are certified to be in compliance with the applicable require-  
ments of UL2601-1, CSA 22.2 No. 601.1, IEC 601-1 (1988), EN 60601-1: 1990.  
Transient Response  
Main Output - 500 μs typical response time for return to within 0.5% of final  
value for a 50% load step within the regulation limits of minimum and maxi-  
mum load, ∆i/∆t< 0.2 A/μs. Maximum voltage deviation is 3.5%.  
Medical Leakage Current  
80 μA under normal conditions (132 Vac @ 60 Hz). Maximum under single fault  
conditions (264 Vac @ 60 Hz) is 180 μA.  
All specifications are typical at nominal input, full load at 25OC unless otherwise stated  

与GLM65E相关器件

型号 品牌 获取价格 描述 数据表
GLM65G SLPOWER

获取价格

65 Watt Multiple Output Global Performance Switchers
GLM65H SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 65W
GLM75 SLPOWER

获取价格

75 Watt Multiple Output Global Performance Switchers
GLM75-12 SLPOWER

获取价格

Power Supply Module
GLM75-15 ETC

获取价格

75 Watt Single Output Global Performance Switchers
GLM75-24 ETC

获取价格

75 Watt Single Output Global Performance Switchers
GLM75-24G ETC

获取价格

75 Watt Single Output Global Performance Switchers
GLM75-28 ETC

获取价格

75 Watt Single Output Global Performance Switchers
GLM75-5 ETC

获取价格

75 Watt Single Output Global Performance Switchers
GLM75A SLPOWER

获取价格

75 Watt Multiple Output Global Performance Switchers