75 Watt Multiple Output Global Performance Switchers

GLM75E 数据手册

 浏览型号GLM75E的Datasheet PDF文件第2页 
GLOBAL PERFORMANCE SWITCHERS  
GLC75 Commercial/GLM75 Medical  
75 Watt Multiple Output Global Performance Switchers  
FEATURES:  
• Cost-effective multiple output power source  
• Universal input 90-264 Vac  
• 7.00”x 4.25”x 1.30” (Meets 1U height)  
• 2-year warranty  
• Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
• Complies with EN61000-3-2 Class A  
• Also available in single output versions  
• Commercial UL1950 3rd Edition, CSA22.2 No. 950 and  
EN60950-1 approvals  
• Medical Approved to UL2601-1,  
CSA22.2 No. 601.1-M90, and IEC/EN60601-1  
• RoHS Compliant Model Available (G suffix)  
SPECIFICATIONS  
Efficiency  
Ac Input  
68ꢀ -78ꢀ depending on model and load distribution.  
90-264 Vac, 47-63 Hz single phase.  
Input Protection  
Input Current  
Internal ac fuse provided on all units. Designed to blow only if a catastrophic  
failure occurs in the unit.  
Maximum input current at 120 Vac, 60 Hz with full rated output load not to  
exceed 2.3 A.  
Inrush Current  
Output Power  
Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac  
half-cycle under cold start conditions will not exceed 37 A.  
Normal continuous output power is 75 W for unrestricted natural convection  
cooling or 110 W with 26 cfm airflow. During peak load conditions output  
regulation may exceed total regulation and noise limits.  
Hold Up Time  
20 ms minimum from loss of ac input power at full load, nominal line (120 Vac).  
Output Regulation  
Measured by 40ꢀ load change from 60ꢀ rated load with all other outputs  
at 60ꢀ rated load and input voltage change from minimum to maximum rat-  
ings. Output #1 requires 1A minimum load for proper regulation of other  
outputs. Initial set tolerance is measured with all outputs at 60ꢀ of full rated  
load. Output #2 requires 0.5A minimum load for proper regulation.  
Temperature Coefficient  
0.03ꢀ/°C typical on all outputs.  
Power Fail  
A standard TTL or CMOS compatible output goes low (< 0.5 V) 5ms before output  
voltage drops more than 4ꢀ below nominal voltage upon loss of ac power. Signal  
is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line  
impedance and distortion. Other settings are available through adjustment of  
built-in potentiometer (consult factory for assistance). Output will stay low for 20  
ms minimum.  
Overload Protection  
Factory set to begin power limiting at approximately 120 W. Fully protected  
against short circuit and output overload. Short circuit protection is cycling  
type power limit.  
Output Noise  
EMI/EMC Compliance  
All models include built-in EMI filtering to meet the following emissions requirements:  
0.5ꢀ rms, 1ꢀ pk-pk, 20 MHz bandwidth, differential mode. Measured with  
noise probe directly across output terminals of the power supply.  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Transient Response  
Main Output: 500μSec typical response time for return to within 0.5ꢀ of final  
value for a 50ꢀ load step change, ∆i/∆t<0.2A/μSec. Maximum voltage devia-  
tion is 3.5ꢀ.  
Conducted Emissions GLC75  
Conducted Emissions GLM75  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
EN55022 Class B; FCC Class B  
EN55011 Class B: FCC Class B  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
EN61000-3-2 Class A  
Overvoltage Protection  
Built in on V1 with firing point set per table. OVP firing reduces output #1 and  
#2 to less than 50ꢀ of nominal voltage in 50 ms.  
Line Frequency Harmonics  
Voltage Adjust  
Commercial Safety  
All GLC models are approved to UL1950 3rd Edition, CSA22.2 No. 950, and  
EN60950-1.  
Factory set on standard unit; however, optional potentiometer (“-Vsuffix)  
adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output.  
Note: Output #1 must not be more than 1ꢀ below nominal to achieve full  
output voltage range on Output #2. Output regulation limits in some models  
may be exceeded when the main output is adjusted beyond +1ꢀ of nominal  
voltage. High voltage settings may degrade the reliability of the unit due to  
excessive power dissipation in some outputs.  
Medical Leakage Current  
70 μA 264 V @ 50 Hz (normal conditions).  
Medical Safety  
GLM models are approved to UL2601-1, CSA22.2 No. 601.1M90, IEC/EN60601-1. CB  
Report available.  
All specifications are typical at nominal input, full load at 25OC unless otherwise stated  

与GLM75E相关器件

型号 品牌 获取价格 描述 数据表
GLM75F SLPOWER

获取价格

75 Watt Multiple Output Global Performance Switchers
GLM75H SLPOWER

获取价格

75 Watt Multiple Output Global Performance Switchers
GLM75J SLPOWER

获取价格

75 Watt Multiple Output Global Performance Switchers
GLM75P SLPOWER

获取价格

75 Watt Multiple Output Global Performance Switchers
GLMC1R003A PANASONIC

获取价格

10 A Synchronous DC-DC Step down Regulator
GLMHR1103A ALPS

获取价格

General Purpose Inductor, 0.11uH, 20%, 1 Element, SMD, CHIP, 2626
GLMHR2303A ALPS

获取价格

General Purpose Inductor, 0.23uH, 20%, 1 Element, SMD, CHIP, 2626
GLMR47KAT1A KYOCERA AVX

获取价格

Ultra-Broadband SMT Inductor
GLMR47KAT1A_13 KYOCERA AVX

获取价格

Ultra-Broadband SMT Inductor
GLN-1/10 ETC

获取价格

Fuse