SMALL DIMENSION (ELECTRONIC) FUSES
1/4” x 1-1/4” Fast-Acting Fuses
AGC
Fast-Acting
ABC
Fast-Acting
GBB
Very Fast-Acting
Physical Size: 1/4” x 1-1/4”
(6.3mm x 32mm)
Construction: Glass Tube, Nickel-
plated brass endcaps.
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Approvals:
UL Listed product meets standard 248-14
UL Listed Card: AGC 1/500-10
UL Recognition Card: AGC 11-30
CSA Component Acceptance Card
(Class No. 1422 30)
Physical Size: 1/4” x 1-1/4”
(6.3mm x 32mm)
Construction: Ceramic Tube
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Approvals:
UL Listed product meets standard 248-14
UL Listed Guide & File numbers (ABC
1/4-15A): JDYX & E19180.
UL Recognition Guide & File numbers
(ABC 20-30A): JDYX2 & E19180.
CSA Certification Record No: 053787
C 000 & Class No: 1422 01 & 1422
30.
Physical Size: 1/4” x 1-1/4”
(6.3mm x 32mm)
Construction: Ceramic Tube
Voltage Rating: See Below
Agency Approvals:
UL recognized product meets standard 248-
14
UL Recognized Card: GBB 1-30A (JFHR2,
E56412)
CSA Component Certified Card (Class
1422-01 File 53787)
CSA Certification Card (Class No.
1422 01)
Electrical Characteristics
Product Code & Voltage Rating
Product
Code
Voltage
Rating
Current Rated
Rating Voltage
AC Interrupting
Electrical Characteristics
AC
DC
1
GBB-1
GBB-1-1/4
GBB-2
GBB-3
GBB-4
GBB-5
GBB-6
GBB-7
GBB-8
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
Rating
Current
Rating
Rated
Voltage
AC Interrupting
Rating
1
AC (Max.) 250V
125V
32V
1/20
1/16
1/10
1/8
3/16
2/10
1/4
250V
250V
250V
250V
250V
250V
250V
250V
250V
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
35V 10000A 1000A
100A 10000A 1000A
100A 10000A 1000A
100A 10000A 1000A
100A 10000A 1000A
100A 10000A 1000A
100A 10000A 1000A
200A 10000A 1000A
200A 10000A 1000A
200A 10000A 1000A
200A 10000A 1000A
200A 10000A 1000A
200A 10000A 1000A
200A 10000A 1000A
AC (Max.) DC (Max.) 250V 125V
1/4
1/2
3/4
1
1-1/2
2
2-1/2
3
4
5
6
7
8
10
12
15
20
25
30
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
35A 10000A
35A 10000A
35A 10000A
35A 10000A
100A 10000A
100A 10000A
100A 10000A
100A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
750A 10000A
400A 1000A
GBB-9
3/10
3/8
GBB-10
GBB-12
GBB-15
GBB-20
GBB-25
GBB-30
45/100 250V
1/2
3/4
1
1-1/4
1-1/2
2
2-1/4
2-1/2
3
4
5
6
7
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
32V
CROSS REFERENCE
OLD
EDISON EDISON BUSS
NEW
–
–
1000A
1000A
GOULD
LF
1Interrupting ratings were measured at 70% - 80% power factor on
AC, and at a time constant described in UL 198L.
GBB GBB
—
None
322
8
9
CROSS REFERENCE
NEW
EDISON EDISON BUSS
ABC BBC ABC
OLD
10
15
20
25
30
GOULD
LF
–
–
–
–
–
–
–
–
1000A
1000A
1000A
1000A
GAB
314
32V
32V
32V
1Interrupting ratings were measured at 70% - 80% power factor on
AC, and at a time constant described in UL 198L.
CROSS REFERENCE
NEW
EDISON EDISON BUSS
AGC BGC AGC
OLD
GOULD
GGC
LF
312
45