NOTES:
FTSH-1XX-XX-XXX-DV-XXX-XXX
C
REVISION FB
1.
REPRESENTS A CRITICAL DIMENSION.
OPTIONS
2. PARTS MAY BE CUT TO POSITION.
No OF POSITIONS
-02 THRU -50
-P: PICK & PLACE PAD (4 POS MIN)
3. MAXIMUM CUT FLASH: .015[0.38],
(SEE FIG 11, SHT 4 & TABLE 5)
LOOSE FLASH MUST BE REMOVED.
(PER ROW)
-TR: TAPE & REEL PACKAGING
4. MINIMUM PUSHOUT FORCE: 1.0 LB.
-ES: END SHROUDS (SEE FIG 6, SHT 3)
5. MEASURED AT BEND RADIUS, NOT AT END OF PIN.
6. TUBE ONLY -04 THROUGH -50 POSITIONS (SEE TABLE 2).
7. SHEAR TAILS TO DIMENSION SHOWN.
LEAD STYLE
DO NOT
SCALE FROM
THIS PRINT
(MOLDED IN 5 POS MIN; -02 & -03 LEAD STYLE ONLY)
(SNAP SHROUDS 9 POS MIN; -02 & -03 LEAD STYLE ONLY)
(MUST USE FTSH-50-D)
-01: .120 [3.05]
-02: .075 [1.91]
8. MAXIMUM BURR ALLOWANCE: .003 [0.08]
-03: .065 [1.65]
-EJ: EJECTOR SHROUDS: SEE FIG 4, SHT 2)
(10 POS MIN; -01 LEAD STYLE ONLY)(MUST USE FTSH-50-D)
-EJM: EJECTOR SHROUDS WITH MOLDED ALIGNMENT PIN
(SEE FIG 5, SHT 2; 10 POS MIN; -01 LEAD STYLE ONLY)
(NOT VALID WITH -A OPTION)(MUST USE FTSH-50-D)
-EJC: EJECTOR SHROUDS WITH LOCKING CLIP
(SEE FIG 5, SHT 2 & NOTE 11)
9. GOLD PLATING TO BE ON POST, TIN PLATING TO BE ON TAIL.
10. FILL WITH ALIGNMENT PIN HOLES TO TAIL SIDE.
11. DUE TO THE HIGH AMOUNT OF INSERTION FORCE NEEDED, LOCKING CLIPS
ARE NOT COMPATIBLE WITH AUTO PLACEMENT. SAMTEC RECOMMENDS
MANUAL PLACEMENT FOR ALL ASSEMBLIES WITH LOCKING CLIPS.
12. VOIDS MAY OR MAY NOT BE PRESENT ON POSITIONS 5 THRU 8 AND CAN
BE MIXED WITHIN AN ORDER.
-04: .150 [3.81]
-05 .170 [4.32]
-14: .150 [3.81](NOT AVAILABLE
WITH -SM, FM, LM PLATING
OPTIONS)
(10 POS MIN; -01 LEAD STYLE ONLY; NOT VALID WITH -A
OPTION)
(MUST USE FTSH-50-D)
PLATING SPECIFICATION
-L: 10µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
13. ON LEAD STYLES -02 THROUGH -03 THE T-1S15-18-XXX CAN
BE SUBSTITUTED FOR T-1S15-16-XXX.
14. ON LEAD STYLES -01 AND -04, T-1S15-17 CAN BE
SUBSTITUTED FOR T-1S15-15-XXX.
-EC: LOCKING CLIP (SEE FIG 7, SHT 3 & NOTE 11)
(9 POS MIN; -02 & -03 LEAD STYLE ONLY)(MUST USE FTSH-50-D)
-EP: GUIDE POST (SEE FIG 8, SHT 3; 9 POS MIN; -02 & -03 LEAD STYLE
ONLY)
-F: 3µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
15. NO TIN PLATING ALLOWED ON THE POST FOR
LEAD STYLES -01, -02, -03 & -04.
-S: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
(USE ONLY WHEN MATING WITH CLP)(MUST USE FTSH-50-D)
-EL: BOARD LOCK (SEE FIG 9, SHT 3)
C
-H: 30µ" GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
+.005 +0.13
(9 POS MIN; -02 & -03 LEAD STYLE ONLY)
No OF POS x .0500
[
]
-.010 -0.25
(USE ONLY WHEN MATING WITH CLP)(MUST USE FTSH-50-D)
-EPC: GUIDE POST & LOCKING CLIP
-LM: 10µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
(No OF POS x .0500[1.27]) - .050[1.27]
(SEE FIG 10, SHT 3 & NOTE 11; USE ONLY WHEN MATING WITH CLP)
(9 POS MIN; -02 & -03 LEAD STYLE ONLY; NOT VALID
WITH -A OPTION)(MUST USE FTSH-50-D)
-FM: 3µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
02
50
-A: ALIGNMENT PIN (MOLDED OR STAKED; SEE FIG 3, SHT 2)
(MOLDED: 3 POS MIN; STAKED: 6 POS MIN)
(SAMTEC DISCRETION ON WHICH -A PIN USED)
(MUST USE FTSH-50-D)
-SM: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-LTL: 10µ" SELECTIVE GOLD IN CONTACT AREA,
TIN/LEAD (90/10+/-5%) TAIL
.135 3.43
REF
-K: KEYING OPTION FOR MATING WITH FFSD
(SEE TABLE 3, SHT 2; 05 THRU 25 AVAILABLE AS STANDARD)
(POSITION 13, 17, 20 & 25 AVAILABLE WITH -EJ OPTION)
(LEAD STYLE -01 ONLY, SEE FIG 2, SHT 2 & NOTE 12)
(ALIGNMENT PIN AVAILABLE WITH -K OPTION BUT MUST BE MOLDED)
(MUST USE FTSH-XX-CN-XX)
-G: 10µ" GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
TAIL OPTION
-DV: DOUBLE VERTICAL
49
01
-M: METAL PICK & PLACE PAD (5 POS MIN; USE MPP-22-5)
(SEE FIG 12, SHT 4; NOT AVAILABLE WITH -K OPTION)
*
FTSH-50-D
2
MAX SWAY
(EITHER DIRECTION)
POLARIZING OPTION
XXX INDICATES POSITION TO BE OMITTED
(NOT AVAILABLE WITH EXX OPTIONS)
(ONLY AVAILABLE WITH -F, -FM, -L, -LM PLATING OPTIONS)
2
MAX SWAY
C
.016 0.41 SQ
REF (TYP)
(EITHER DIRECTION)
.050±.008 1.27±0.20
SEE TABLE 1
* = NOT ENGINEERING APPROVED
2
MAX SWAY
(EITHER DIRECTION)
C
"B"
90°±3°
CONTACT AREA
"A"
C
(SEE NOTE 9 & TABLE 1)
+.005
-.003
+0.13
2.92
-0.08
.099 2.51
REF
.115
(SEE NOTE 5)
SEE NOTE 3
(2 PLCS)
.004[.10]
FIG 1
.23 5.8
(SEE NOTE 7)
PATENT NUMBERS
.230 5.84 REF
HAND FILL USING T-1S40
5713755 / 5961339
FTSH-1XX-XX-XXX-DV SHOWN
SEE NOTE 8
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
*
*
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
TOLERANCES ARE:
DECIMALS
ANGLES
1
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
.XXX: .005 [.13]
PHONE: 812-944-6733
e-Mail info@SAMTEC.com
DESCRIPTION:
FAX: 812-948-5047
.XXXX: .0010 [.025]
code 55322
SHEET SCALE: 5:1
MATERIAL:
DO NOT SCALE DRAWING
.050 x .050 CL DOUBLE VERTICAL SMT TERMINAL STRIP
INSULATOR: LCP UL 94 VO
TERMINAL: PHOSPHOR BRONZE
DWG. NO.
FTSH-1XX-XX-XXX-DV-XXX-XXX
* = SEE NOTE 13
*** = SEE NOTE 14
10/12/1995 SHEET 1 OF
BY: PURVIS
5
F:\DWG\MISC\MKTG\FTSH-1XX-XX-XXX-DV-XXX-XXX-MKT.SLDDRW