12 ~ 18W AC-DC Single Output Interchangeable Wall-mounted type
GE18 series
Features :
Interchangeable AC plugs (plug kit sold seperately)
Universal AC input / Full range
No load power consumption< 0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act) for 5~48V
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Pass LPS
Approvals: UL / CUL / TUV / CCC / CB / FCC / CE / C-Tick
2 years warranty
AC INLET PLUG
TYPE
Australian type
AC plug-AU
U.K type
European type
AC plug-EU
US type
Mix four type
AC plug-MIX
AC plug-UK
AC plug-US
ORDER NO.
SPECIFICATION
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
GE18
I
05-P1J GE18
I
07-P1J GE18
I
09-P1J GE18
I
12-P1J GE18
I
15-P1J GE18
I
18-P1J GE18
I
24-P1J GE18I48-P1J
I I I I I I I
FRA018-S05- FRA018-S07- FRA018-S09- FRA018-S12- FRA018-S15- FRA018-S18- FRA018-S24- FRA018-S48-
I
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
2.4A
1.73A
0 ~ 1.73A
13W
2.0A
1.5A
1.2A
1.0A
0.75A
0 ~ 0.75A
18W
0.375A
0 ~ 0.375A
18W
0 ~ 2.4A
12W
0 ~ 2.0A
18W
0 ~ 1.5A
18W
0 ~ 1.2A
18W
0 ~ 1.0A
18W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
75mVp-p
5.0%
100mVp-p
5.0%
120mVp-p
3.0%
150mVp-p
3.0%
180mVp-p
3.0%
240mVp-p
3.0%
300mVp-p
3.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
3.0%
SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC
4000ms, 100ms, 10ms / 115VAC at full load
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
90 ~ 264VAC
47 ~ 63Hz
75%
135 ~ 370VDC
79%
0.4A / 230VAC
81%
82%
84%
84%
85%
85%
INPUT
0.7A / 100VAC
INRUSH CURRENT (max.)
COLD START 40A / 100VAC 80A / 230VAC
LEAKAGE CURRENT (max.) 0.25mA / 240VAC
110% ~ 200% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
115% ~ 135%
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Clamp by zener diode
-10 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
LIFE
UL60950-1, CSA C22.2, TUV EN60950 -1, CCC GB4943 approved
I/P-O/P:4242VDC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
2 years : 100% load 30 , 8 hours / day
MTBF
100Khrs min. MIL-HDBK-217F (25
)
OTHERS
DIMENSION
81*43*40.5mm (L*W*H)
134g ; 60pcs / 12.32kg / CARTON
PACKING
Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requested
See page2
PLUG
DC OUTPUT
CONNECTOR
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug.
File Name:GE18-SPEC 2011-06-14