Data Sheet
2.0 Amp FAST RECOVERY
PLASTIC RECTIFIERS
Mechanical Dimensions
Description
.230
.300
1.00 Min.
JEDEC
D0-15
.104
.140
.031 typ.
Features
n FAST SWITCHING FOR
HIGH EFFICIENCY
n 2.0 AMP OPERATION @ TA = 55°C, WITH
NO THERMAL RUNAWAY
n HIGH SURGE CAPABILITY
n MEETS UL SPECIFICATION 94V-0
Units
FR20 . . . 210 Series
FR20
FR21
FR22
FR24
FR26
FR28
FR210
Maximum Ratings
Volts
Volts
Volts
Peak Repetitive Reverse Voltage...VRRM
RMS Reverse Voltage...VR(rms)
DC Blocking Voltage...VDC
50
35
50
100
70
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
100
1000
Average Forward Rectified Current...IF(av)
TA = 55°C
............................................. 2.0 ............................................... Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Current & Temp
............................................. 60 ............................................... Amps
Operating & Storage Temperature Range...TJ, TSTRG
........................................ -65 to 150 .........................................
°C
Electrical Characteristics
Maximum Forward Voltage @ 2.0A...VF
............................................. 1.3 ............................................... Volts
Maximum DC Reverse Current...IR
@ Rated DC Blocking Voltage
@
@
25°C
100°C
............................................. 5.0 ............................................... µAmps
............................................. 10 ............................................... µAmps
Typical Junction Capacitance...CJ (Note 1)
............................................. 25 ...............................................
150 150 150 150 250 500 500
pF
ns
Maximum Reverse Recovery Time...tRR
Page 4-10