FR201 THRU FR207
FAST RECOVERY RECTIFIERS
Reverse Voltage – 50 to 1000 Volts
Forward Current – 2.0 Amperes
Features
•
•
•
•
High Current Capability
Fast switching for high efficiency
Low Leakage.
2 ampere operation at TA = 55℃ with no thermal runaway
Mechanical Data
•
•
•
•
Case: Molded plastic, DO-15
Lead: Axial leads, solderable per MIL-STD-202, method 208 guaranteed.
Polarity: Color band denotes cathode end
Mounting Position: Any
Absolute Maximum Ratings and Characteristics
Ratings at 25℃ ambient temperature unless otherwise specified, single phase, half wave, 60Hz,
resistive or inductive load, for capacitive load, derate current by 20%.
FR
FR
FR
FR
FR
FR
FR
Symbols
Units
201
202
203
204
205
206
207
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
VRRM
VRMS
VDC
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
Volts
Volts
Volts
Average forward rectified current .375” (9.5mm)
lead length at TA = 55℃
Peak forward surge current
I(AV)
IFSM
VF
2
Amp
Amps
Volts
8.3ms single half sine-wave
70
1.3
superimposed on rated load (JEDEC method)
Maximum forward voltage
at 2A DC and 25oC
TA = 25℃
TA = 100℃
5
500
Maximum reverse current
at rated DC blocking voltage
µA
IR
Maximum reverse recovery time (Note 1)
Typical junction capacitance (Note 2)
Trr
CJ
150
250
500
nS
pF
35
22
Typical thermal resistance (Note3)
Operating and storage temperature range
R
Θ
℃/W
℃
JA
TJ ,TS
-55 to +150
1) Reverse recovery test conditions: IF = 0.5A, IR = 1A, Irr = 0.25A.
2) Measured at 1MHZ and applied reverse voltage of 4 VDC .
3) Thermal resistance junction to ambient and form junction to lead at 0.375” (9.5mm) lead length P.C.B. mounted.
SEMTECH ELECTRONICS LTD.
(Subsidiary of Semtech International Holdings Limited, acompany
listed on the Hong Kong Stock Exchange, Stock Code: 724)
®
Dated : 23/08/2004