Sensing element/Gauge
FHM Data sheet
■Features
Horizonral pressure port
■Ordering Information
FHM-07P G R
Terminal leadsdirection
Model
No Mark:
Rated Pressure
(PSI)
Pressure type
G:Gauge Pressure
R :
Weight
(grams)
RoHS compliance
0.6
Measurable pressure
range(kPa)
Part number
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
-98.07 to 103.4
-98.07 to 206.8
-98.07 to 344.7
-98.07 to 482.6
-98.07 to 827.4
FHM-02PG
FHM-05PG
FHM-02PGR
FHM-05PGR
FHM-07PGR
FHM-15PGR
FHM-30PGR
FHM-50PGR
FHM-70PGR
FHM-120PGR
FHM-07PG
FHM-15PG
FHM-30PG
FHM-50PG
FHM-70PG
FHM-120PG
■Specifications
Model
02PG
05PG
07PG
15PG
30PG
50PG
70PG
120PG
Unit
Recommended operating conditions
Pressure type
Gauge pressure
-
Rated pressure
13.79
34.47
48.26
103.4
206.8
344.7
482.6
827.4
kPa
-13.79
-34.47
-48.26
-98.07
-98.07
-98.07
-98.07
-98.07
Measurable pressure range
kPa
to 13.79 to 34.47 to 48.26 to 103.4 to 206.8 to 344.7 to 482.6 to 827.4
Temperature range
Pressure media
Excitation current (Constant)
Absolute maximum rating
0 to 50
deg.C
-
mADC
Non-corrosive gases only (No liquid)
1.5
1.5 times
of rating
pressure
Twice of rated pressure
Maximum load pressure
-
Maximum excitation current
Operating temperature
Storage temperature
Operating humidity
3.0
-20 to 100
-40 to 120
mADC
deg.C
deg.C
%RH
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage
60 to 140 (at 0kPa to rated pressure)
mV
mV
Ω
msec.
%FS/0-
Offset voltage
Bridge resistance
Response time
+/-20 (at 0kPa)
4000 to 6000
2 (for the reference)
+/-5
Accuracy
TSO*
TCS*
50deg.C
2.5
Linearity
Pressure hysteresis
+/-0.5
+/-0.4
+/-0.3
+/-0.2
+/-0.5
+/-0.6
%FS
%FS
+/-0.4
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)