Sensing element/Gauge
FPM,FHM Data sheet
Features
Applications
Industrial instrumentation
.
.
.
.
.
Dual-In-line-Package(DIP)or Horizontal pressure port, Easy
to mount on PCB
Pressure switch, Pneumatic device
Medical device
.
.
Vacuum pressure measurable
Non-corrosive liquid measurable(FPMC/FHMC available)
Part number for ordering
Turbo boost pressure measurement for Automotive system
FPM C - 07P G R
Terminal leads direction(See Outline Diagram)
Rated pressure
(PSI)
No mark
:
Model
FPM
FHM
R
:
Pressure type
G : Gauge pressure
Available pressure media
No mark : Non-corrosive gas only
C : Non-corrosive gas and liquid(Contact us about availability)
Pressure type
Gauge pressure
FPM
FHM
Model
Package configuration
Dual-In-line-Package(DIP)
Horizontal pressure port DIP
Measurable pressure range(kPa)
13.79 13.79
Part number for ordering
FPM-02PGR FHM-02PG
FPM-02PG
FHM-02PGR
FHM-05PGR
FHM-07PGR
FHM-15PGR
FHM-30PGR
FHM-50PGR
FHM-70PGR
FHM-120PGR
34.47 34.47
48.26 48.26
98.07 103.4
98.07 206.8
98.07 344.7
98.07 482.6
98.07 827.4
FPM-05PG
FPM-07PG
FPM-15PG
FPM-30PG
FPM-50PG
FPM-70PG
FPM-120PG
FPM-05PGR
FPM-07PGR
FPM-15PGR
FPM-30PGR
FPM-50PGR
FPM-70PGR
FPM-120PGR
FHM-05PG
FHM-07PG
FHM-15PG
FHM-30PG
FHM-50PG
FHM-70PG
FHM-120PG
Specifications
Model/Rated pressure
02PG
05PG
07PG
15PG
30PG
50PG
70PG
120PG
unit
Recommended operating conditions
Pressure type
Gauge pressure
13.79
Rated pressure
34.47
0.352
48.26
0.492
103.4
1.055
206.8
2.109
344.7
3.516
482.6
4.922
827.4
8.437
kPa
kg/cm2
0.141
13.79
Measurable pressure range
13.79
34.47
34.47
48.26
48.26
98.07
103.4
98.07
206.8
98.07
344.7
98.07
482.6
98.07
827.4
kPa
Pressure media
FPM, FHM : Non-corrosive gas only, FPMC, FHMC : Non-corrosive gas and liquid
1.5
Excitation current(Constant)
Absolute maximum rating
Maximum load pressure
Maximum excitation current
Operating temperature
Storage temperature
mADC
Twice of rated pressure
1.5times of rated pressure
3
20 100
mADC
RH
40 120
Operating humidity
30 80(No dew condensation)
Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25
)
Full scale span voltage
Offset voltage
60 140
mV
mV
20
Bridge impedance
Mechanical response time
Temperature sensitivity of offset(TSO)
Temperature coefficient of sensitivity(TCS)
Linearity
4000 6000
2(For the reference)
msec
FS/0 50
FS/0 50
FS
5
2.5
0.5
0.4
0.3
0.5
0.6
Pressure hystersis
0.2
0.4
FS
Please consult us available liquid pressure media when you choose the C models.
1