MODEL: FFL
(Operational voltage range 170 – 264 V, 47 – 66 Hz)
Space-saving Plug-in Signal Conditioners F-UNIT
DC Power
R: 24 V DC
SQUARE ROOT EXTRACTOR
(non-isolated)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
Functions & Features
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
• Provides a DC output proportional to the root of input
signal
[3] OPTIONS
• Low-end cutout
blank: none
/Q: With options (specify the specification)
Typical Applications
• Converting differential pressure to flow
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
26 (1.02)
/C02: Polyurethane coating
/C03: Rubber coating
100
(3.94)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
137
(5.39)
GENERAL SPECIFICATIONS
Construction: Plug-in
mm (inch)
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
MODEL: FFL–[1]6–[2][3]
Housing material: Flame-resistant resin (black)
Isolation: Input or output to power
Overrange output: 0 – 105 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Low-end cutout: Approx. 4 – 8 % (output)
ORDERING INFORMATION
• Code number: FFL-[1]6-[2][3]
Specify a code from below for each [1] through [3].
(e.g. FFL-66-K/Q)
• Specify the specification for option code /Q
(e.g. /C01/S01)
[1] INPUT
Current
8% or less
A: 4 – 20 mA DC (Input resistance 250 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
Voltage
4% or more
0
INPUT
6: 1 – 5 V DC (Input resistance 100 kΩ min.)
INPUT SPECIFICATIONS
■ DC Current:
Shunt resistor attached to the input terminals (0.5 W)
OUTPUT
Voltage
6: 1 – 5 V DC (Load resistance 10 kΩ min.)
INSTALLATION
Power consumption
•AC: Approx. 4.5 VA
[2] POWER INPUT
AC Power
•DC: 24 V approx. 70 mA
110 V approx. 20 mA
K: 85 – 132 V AC
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
L: 170 – 264 V AC
FFL SPECIFICATIONS
ES-1445 Rev.8 Page 1/3
http://www.m-system.co.jp/