IEC Inlet Filters
F.MF-F.MG series
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
Current ratings from 1A to 6A
•
Integral single or twin fuse holder
•
Voltage selector
•
Snap-in or screw mount versions
•
Medical versions available
•
Filter Range
Mechanical Specifications
(example pt no. - F.MF.01A.01.01.FA)
Manufacture: metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
R
L
Code
l
L
Cx
Cy
I
R
(A) (mH)
(µF)
(pF)
(mA)
(MΩ
)
01.– –.– –
01A. 04.– –.– –
07.– –.– –
2 x 2500
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
3
6
2 x 10 0.047
2 x 2.5 0.047
1
1
1
F.MF.
02.– –.– –
2 x 2500
2 x 2500
Connections: IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
F.MG. 03A. 05.– –.– –
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 1
0.047
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
Electrical Specifications
R
Rated voltage (V ): max 250V, 50/60Hz
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
R
Rated current (I ): referred to room temperature = 40°C
F = 1 fuse
G = 2 fuses
L
Leakage current (I ):at 220V, 50Hz, max value
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
S
Voltage test (2 .): line to ground 3000Vdc or 1800Vac
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
line to line 1700Vdc
Climatic category: HPF (25/085/21);
Temperature range: -25°C to +85°C
Voltage selector:
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac