IEC Inlet Filters
F.MA-F.MB-F.MC-F.MD series
With fuse holders and mains switch
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus a unipolar or bipolar
rocker switch.
Designed for use in business, consumer and medical equipment,
VDU’s, vending machines and many other general purpose
applications.
Current ratings from 1A to 6A
•
Integral single or twin fuse holder
•
Unipolar or bipolar rocker switch
•
Snap-in or screw mount versions
•
Medical versions available
•
Filter Range
Mechanical Specifications
(example pt no. - F.MA.01A.01.07.FA)
Manufacture: metal case with built-in power line connector
according to IEC 60320,
R
L
Code
l
L
Cx
Cy
I
R
1 (F.MA-F.MC) or 2 (F.MB-FMD) fuse holders for
fuses 5 x 20mm (IEC) or 6.3 x 32mm (US),
unipolar (F.MA-F.MB) or bipolar (F.MC-F.MD)
rocker switch;
(A) (mH)
(µF)
(pF)
(mA)
(M
Ω)
01.– –.– –
01A. 04.– –.– –
07.– –.– –
2 x 2500
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
3
6
2 x 10 0.047
2 x 2.5 0.047
1
1
1
F.MA.
02.– –.– –
2 x 2500
2 x 2500
internal components sealed with self-extinguishing
resin.
F.MB. 03A. 05.– –.– –
F.MC.
F.MD.
08.– –.– –
03.– –.– –
Connections: IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
06A. 06.– –.– –
09.– –.– –
2 x 1
0.047
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
faston 2.8 x 0.5mm for fuse terminals;
faston 4.8 x 0.8mm for rocker switch terminals;
ground terminal connected to case.
G = Screw mounting
07 = Fuse 5 x 20mm
14 = Fuse 6.3 x 32mm
Electrical Specifications
A = 1 Fuse + unipolar rocker switch
B = 2 Fuses + unipolar rocker switch
C = 1 Fuse + bipolar rocker switch
D = 2 Fuses + bipolar rocker switch
R
Rated voltage (V ): max 250V, 50/60Hz
R
Rated current (I ): referred to room temperature = 40°C
L
Leakage current (I ):at 220V, 50Hz, max value
S
Voltage test (2 .): line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
Climatic category: HPF (25/085/21);
Temperature range: -25°C to +85°C
Rocker switches: 6(4)A / 250Vac (Rated current),
50000 on-off operations;
10(4)A / 250Vac (Rated current),
10000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Approvals
27