Thermal Cutoffs (TCO)
Thermal Cutoffs (TCO)/
Thermal-links
Series:
EYP
N
Series:
Series:
Series:
Series:
Series:
Series:
F
E
H
MP
ML
MU
■ Features
Small and Insulation Type
●
TCO is compact and insulated, featuring quick temperature response, and mountable in a small space without
insulation or protection.
High Reliability
●
●
●
TCO opens reliably when the equipment becomes abnormal, and is not resettable.
Solid Structure
Unique formed lead provides reliable TCO connection and provides easy assembly handling. (Axial lead type only)
Thin Type
Thick is less than 0.8 mm (MP and ML series), available for spot welding (MP, ML and MU series)
■ Approved Safety Standards
Recommended Applications
■
PS
● Transformers, Solenoids, Ventilation fans, Electric
fans, Small electric motors, Driers, Gas home appliances,
Fluorescent lights, Electric shavers, Adaptors, Heating
devices, ICs, Batteries, etc. The TCO can also be used
for overheating protection.
●
E
(Japan)
: Approved by JET
: E60271
● UL, C-UL (U.S.A.)
● CSA
● VDE
● BEAB
● CCC
(Canada) : 1ꢀꢀꢀꢀꢀꢀ (LR67163)
(Germany) : 481106-1171-ꢀꢀꢀꢀ
(U.K.)
: Cꢀꢀꢀꢀ
(China)
: 20020102050042ꢀꢀ
See Ratings in details.
■ Construction
● Axial lead type (N, F and E series)
● Radial lead type (H series)
Sealant (Epoxy resin)
Fusible alloy (Pb·Cd free)
Fusible alloy
(Pb·Cd free)
Insulating
case(Ceramic)
Special formed
lead wire
(Tin plating copper)
Special resin
Insulating
case (Ceramic)
(Flux)
Special resin
(Flux)
● Thin type (MP, ML and MU series)
✽ Thin type is not to be soldered.
Insulating film
Fusible alloy
(Pb·Cd free)
Lead wire
(Tin plating copper)
Sealant
(Epoxy resin)
Special resin
(Flux)
Terminal
(Ni or Ni plating)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Jul. 2008