EXQ125 Series
S i n g l e o u t p u t
DC/DC CONVERTERS 36-100W High Efficiency DC/DC Converters
1
• Ultra-high efficiency topology, 91% at 3.3V,
88% typical at 1.8V
• Industry standard footprint
• Wide baseplate temperature, -40°C to +100°C
• 90% to 110% output trim
• No minimum load
• Overvoltage protection
• Remote on/off
The EXQ125 is a new ultra-high efficiency, open frame, isolated converter series in
an industry standard quarter-brick footprint that provides up to 100 watts of output
power. The EXQ125 delivers very high output current at low voltages, and excellent
useable power density for today’s high end applications. The seven models in the
series feature an input voltage range of 33 to 75VDC and are available in output
voltages of 12V, 5V, 3.3V, 2.5V, 1.8V, 1.5V and 1.2V. The output voltage on each
model is adjustable from 90% to 110% of the nominal value. The EXQ125 series
also has a remote on/off capability. Overcurrent and overvoltage protection features
are included as standard. With full international safety approval including EN60950
(TÜV Rheinland) and UL/cUL1950, the EXQ125 reduces compliance costs and time
to market.
TÜV
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
EMC CHARACTERISTICS
90% to 110%
±1.5% max.
±0.1% max.
0.2% max.
0A
Conducted emissions
EN55022 (See Note 2)
Level A
Level B
Level B
EN55022 (See Note 2)
Set point accuracy
Radiated emissions
Immunity:
EN55022
Line regulation
Load regulation
Minimum load
Overshoot
Low line to high line
ESD air
ESD contact
EN61000-4-2 8kV (NP), 15kV (NP)
EN61000-4-2 6kV (NP), 8kV (NP)
Full load to min. load
Radiated field enclosure EN61000-4-3 10V/m (NP)
Conducted (DC power) EN61000-4-6 10V (NP)
Conducted (signal)
Input transients
EN61000-4-6 10V (NP)
ETS 300 132-2, ETR 283
At turn-on and turn-off
None
Undershoot
1.2V, 1.5V, 1.8V, 2.5V
and 3.3V models
None
GENERAL SPECIFICATIONS
Ripple and noise
5Hz to 20MHz
60mV pk-pk
20mV rms
Efficiency
See table
Operational
Input/output
Input/baseplate
1500VDC
1500VDC
Transient response
(See Note 1)
2% typ. deviation
100µs recovery to
within 1% of setpoint
Switching frequency
Fixed
400kHz typ.
Approvals and
standards (See Note 4)
EN60950 (TÜV Rheinland)
UL/cUL1950
INPUT SPECIFICATIONS
Input voltage range
Input current
48Vin nominal
33 to 75VDC
Material flammability
Weight
UL94V-0
No load
Remote OFF
85mA
20mA
45g (1.6oz)
MTBF
MIL-HDBK-217F
@ 25°C, 100% load
ground benign
>300,000 hours
Input current (max.)
(See Note 3)
3.5A max. @ Io max.
and Vin = 33 to 75V
Input reflected ripple
(See Note 5)
300mA (pk-pk) typ.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating baseplate
Active high remote ON/OFF
Logic compatibility
ON
OFF
(See Note 7)
Open collector ref to -input
Open circuit or >4.0VDC
<1.2VDC
-40°C to +100°C
-40°C to +125°C
temperature
Non-operating
Undervoltage lockout
Power up
Power down
32.5V (typ)
30.5V (typ)
Start-up time
(See Note 6)
Power up
Remote ON/OFF
6ms (typ)
2ms (typ)
File Name: EXQ125S.PDF Rev: 18 June 2002