APPLICABLE STANDARD
Operating temperature
Storage temperature
range
Operating humidity range
1
-40 C to 70 C
-55C to 60C
RATING Voltage
Current
AC 125 V
95% max
Signal contact
Power contact
:
:
0.5 A
3 A
Applicable cable
―
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
x
x
Marking
X
ELECTRIC CHARACTERISTICS
Signal contact resistance : 70 m max.
Power contact resistance : 40 m max.
Contact Resistance
100 mA (DC OR 1000 Hz).
X
x
Gnd contact resistance
: 50 m max.
Insulation Resistance
Voltage Proof
250 V DC.
300 M min.
-
X
X
350 V AC for 1 min.
No flashover or breakdown.
x
MECHANICAL CHARACTERISTICS
Insertion force 24 N max.
Extraction force 20 N max.
Insertion and Extraction
-
X
X
X
X
Measured by applicable connector.(Except shutter)
Force
Mechanical Operation
5000 times insertions and extractions.
1) Signal contact resistance : 100 m max
Power contact resistance : 70 m max
Gnd contact resistance : 100 m max
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 1 s.
2) Signal contact resistance : 100 m max
Power contact resistance : 70 m max
Gnd contact resistance
-
-
-
Vibration
Shock
Frequency 10 to 55 Hz, amplitude 0.75 mm,
at 2 h, for 3 directions.
: 100 m max
Acceleration 490 m/s2.
Directions of pulse 11 ms at 3 times in 3 both axial
directions.
3) No damage, crack and looseness of parts.
Half sine wave.
ENVIRONMENTAL CHARACTERISTICS
Rapid Change of
Temperature
-55 → 15~35 → 85 → 15~35 c
30 → 2~3 → 30 → 2~3 min.
1) Signal contact resistance: 100 m max.
Power contact resistance: 70 m max.
Gnd contact resistance : 100 m max.
2) Insulation resistance : 100 M min.
3) No damage, crack and looseness, of parts.
1) Signal contact resistance: 100 m max.
Power contact resistance: 70 m max.
Gnd contact resistance : 100 m max.
2) Insulation resistance : 5 M min.(After dry)
3) No damage, crack and looseness, of parts.
No damage, crack and looseness, of parts
X
X
X
-
-
-
Temperature
Time
Under 5 cycles.
Damp Heat
Exposed at 60 c, 90~95 %, 96 h.
(Steady State)
Corrosion Salt Mist
Exposed in 5 % salt water spray for 48 h.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
1
APPROVED
CHECKED
DESIGNED
DRAWN
MN.KENJO
20200407
20200407
20200407
20200407
The operation temperature includes the rise by current carrying.
TU.TANIGUCHI
KIM JAEHYEON
DS.HIROWATARI
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-123446-75-00
EX80-54(50)S-SH(75)
SPECIFICATION SHEET
0
1/1
HIROSE ELECTRIC CO., LTD.
CL232-0606-5-75
△
FORM HD0011-2-1