14.Humidity (Steady state)
Temperature Compensating(High Frequency type)
Appearance
: No abnormality
Capacitance change
Insulation resistance
: C※≦10pF :±0.5pF C※>10pF :±5% ※Normal capacitance
: 1000MΩmin
Specified Value
High permittivity
Appearance
: No abnormality
: Within±15%
Capacitance change
Dissipation factor
Insulation resistance
: 7%max(HMK,HMJ), 5%max(QMK,QMJ, SMK,SMJ).
: 25MΩμF or 1000MΩ, whichever is smaller.
Preconditioning
Temperature
Humidity
: Thermal treatment(at 150℃ for 1hr) Note1 (Only High permittivity)
: 40±2℃
Test Methods and
Remarks
: 90 to 95%RH
Duration
: 500 +24/-0 hrs
Recovery
: 24±2hrs under the standard condition Note3
15.Humidity Loading
Temperature Compensating(High Frequency type)
Appearance
: No abnormality
Capacitance change
: C※≦2.0pF :±0.4pF 2.0pF<C≦10pF : ±0.75pF C※>10pF :±7.5%
: ※Normal capacitance
: 500MΩmin
Insulation resistance
Specified Value
High permittivity
Appearance
: No abnormality
Capacitance change
Dissipation factor
Insulation resistance
: Within±15%
: 7%max(HMK,HMJ), 5%max(QMK,QMJ, SMK,SMJ).
: 10MΩμF or 500MΩ, whichever is smaller.
According to JIS 5102 clause 9.9.
Preconditioning
Temperature
: Voltage treatment Note2 (Only High permittivity)
: 40±2℃
Test Methods and Humidity
Remarks Applied voltage
: 90 to 95%RH
: Rated voltage
Charge/discharge current
Duration
: 50mA max.
: 500 +24/-0 hrs
: 24±2hrs under the standard condition Note3
Recovery
16.High Temperature Loading
Appearance
Temperature Compensating(High Frequency type)
: No abnormality
Capacitance change
: C※≦10pF :±0.3pF C※>10pF :±3%
:1000MΩmin
Insulation resistance
Specified Value
High permittivity
Appearance
: No abnormality
Capacitance change
Dissipation factor
Insulation resistance
: Within±15%
: 7%max(HMK,HMJ), 5%max(QMK,QMJ, SMK,SMJ).
: 50MΩμF or 1000MΩ, whichever is smaller.
According to JIS 5102 clause 9.10.
Preconditioning
Temperature
: Voltage treatment Note2 (Only High permittivity)
: Maximum operating temperature
Test Methods and
Remarks
Applied voltage
Charge/discharge current
Duration
: Rated voltage×2(HMK,HMJ,QVS) Rated voltage×1.5(QMK,QMJ) Rated voltage×1.2(SMK,SMJ)
: 50mA max.
: 1000 +24/-0 hrs
Recovery
: 24±2hrs under the standard condition Note3
Note1 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperature
for 24±2hours.
Note2 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in
the test conditions, and kept at room temperature for 24±2hours.
Note3 Standard condition : Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted
under the following condition.
Temperature: 20±2℃, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Unless otherwise specified, all the tests are conducted under the "standard condition".
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .