5秒后页面跳转
EM10DINAV71X01P PDF预览

EM10DINAV71X01P

更新时间: 2022-12-16 16:09:39
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
4页 134K
描述
Energy Management Energy Meter

EM10DINAV71X01P 数据手册

 浏览型号EM10DINAV71X01P的Datasheet PDF文件第2页浏览型号EM10DINAV71X01P的Datasheet PDF文件第3页浏览型号EM10DINAV71X01P的Datasheet PDF文件第4页 
Energy Management  
Energy Meter  
Type EM10 DIN  
Class 1 (kWh) according to EN62053-21  
Energy meter  
Energy: 5+1 DGT  
Energy measurements: total kWh  
TRMS measurements of distorted sine waves (volt-  
ages/currents)  
Self power supply  
Dimensions: 1-DIN module  
Protection degree (front): IP40  
1 pulse output on request  
MID “annex MI-003” (Measuring Instruments Directive)  
compliant  
Product Description  
How to order  
Model  
Range code  
System  
Power supply  
Output  
EM10 DIN AV8 1 X O1 X  
One-phase energy meter  
with LCD data displaying;  
indicated for active energy  
metering. Housing for DIN-  
rail mounting, IP40 (front)  
protection degree. Direct  
connection up to 32A.  
Moreover the meter can be  
provided with pulse output  
proportional to the active  
energy being measured.  
Option  
Type Selection  
Range code  
System  
Power supply  
Output  
AV7: 120VLN AC - 5(32)A (**)  
(direct connection)  
AV8: 230VLN AC - 5(32)A (*)  
(direct connection)  
1:  
1-phase  
X:  
Self power supply  
(from 48 to 62Hz).  
The instrument  
works on the range  
from -20% to +20%  
of the measuring  
nominal input  
XX:  
O1:  
None (*)  
Pulse type (open col-  
lector output) (*)  
Option  
(*) as standard.  
(**) on request.  
X:  
P:  
None (*)  
PTB approval  
voltage.  
Input specifications  
Rated inputs  
Current range (by shunt)  
Voltage range  
System: 1  
Display  
1 line (max: 5+1 DGT)  
LCD, h 7mm  
Total: 5+1 DGT  
AV7 and AV8: 5(32)A  
AV7: 120 VLN AC  
AV8: 230 VLL AC  
Type  
Energie indication  
LEDs  
Red LED (Energy con-  
Accuracy (Display)  
sumption), 1000 pulses/kWh  
(Max Frequency 16 Hz)  
according to EN62053-11  
(@25°C 5°C, R.H. 60%, 48 to 62Hz)  
AV7 model  
Ib: 5A, Imax: 32A;  
Un: 120VLN (-20% +20%)  
Ib: 5A, Imax: 32A;  
Un: 230VLN (-20% +20%)  
Measurements  
kWh from 0,0 to 99999,9  
TRMS measurements of  
distorted wave forms  
Direct  
AV8 model  
Method  
Coupling type  
Crest factor  
Current Overload  
Continuous  
For 10ms  
Voltage Overload  
Continuous  
For 500ms  
Input impedance  
120VL-N (AV7)  
230VL-N (AV8)  
Active energy  
Class 1 according to  
EN62053-21 and MID  
Annex MI-003 Class B.  
Ib: 5A, Imax: 32A,  
0.1 Ib: 0.5A  
Ib 5A 4 (45A max. peak)  
32A, @ 50Hz  
960A, @ 50Hz  
Reference values  
Start up current:  
Energy additional errors  
Influence quantities  
20mA  
1.2 Un  
2 Un  
According to EN62053-21,  
EN62053-23  
200ppm/°C  
1600 samples/s @ 50Hz  
1900 samples/s @ 60Hz  
>720KΩ  
>720KΩ  
< 0.5VA  
Temperature drift  
Sampling rate  
5(32) A (AV7-AV8)  
Frequency  
48 to 62 Hz  
Specifications are subject to change without notice EM10DINDS270906  
1

与EM10DINAV71X01P相关器件

型号 品牌 描述 获取价格 数据表
EM10DINAV71XP ETC Energy Management Energy Meter

获取价格

EM10DINAV81X ETC Energy Management Energy Meter

获取价格

EM10DINAV81X01 ETC Energy Management Energy Meter

获取价格

EM10DINAV81X01P ETC Energy Management Energy Meter

获取价格

EM10DINAV81XP ETC Energy Management Energy Meter

获取价格

EM10Q100 PROTEC LCD - EMI FILTER/TVS ARRAY

获取价格