8
7
5
4
3
2
1
6
REVISIONS
REV.
C
ECO. NO
1662
DESCRIPTION
DATE
BY
VJ
PART NUMBER CODING
_ _ M _ _ D_ _ _
UPDATE DRAWING FORMAT &
PART NUMBER CODING
4/23/2008
D
E
1771
1808
TABULATE DRF, DRU AND DRP TERMINATIONS
ADD 'D' MOUNTING, UPDATE FORMAT
7/29/2008
9/23/2008
MNH
ASK
MATERIAL (INSULATOR/CONTACT)
E = PBT/PHOSPHOR BRONZE
MOUNTING STYLE
H = .125" DIA. CLEARANCE HOLES
N = NO MOUNTING EARS
S = .125" DIA. SIDE MOUNTING
I = #4-40 THREADED INSERT
F = FLOATING BOBBIN
F
F
OPERATING TEMP: -65°C TO +125°C @ 3 AMPS PER CONTACT
OPERATING TEMP: -65°C TO +21°C @ 5 AMPS PER CONTACT
PROCESSING TEMP: 260°C FOR 10 SECS MAX
R = PPS/PHOSPHOR BRONZE
OPERATING TEMP: -65°C TO +125°C
D = FLUSH MOUNTING
PROCESSING TEMP: 260°C FOR 120 SECS MAX
CURRENT RATING PER CONTACT: 5 AMPS
TAIL LENGTH ±.025[.64]
RX = .137[3.48]
G = PA9T/PHOSPHOR BRONZE
OPERATING TEMP: -65°C TO +125°C
RF = .200[5.08]
PROCESSING TEMP: 260°C FOR 120 SECS MAX
CURRENT RATING PER CONTACT: 5 AMPS
H = PBT/BERYLLIUM COPPER
OPERATING TEMP: -65°C TO +125°C @ 3 AMPS PER CONTACT
OPERATING TEMP: -65°C TO +105°C @ 5 AMPS PER CONTACT
PROCESSING TEMP: 260°C FOR 10 SECS MAX
A = PPS/BERYLLIUM COPPER
RU = .225[5.71]
RP = .408[10.40]
E
E
NUMBER OF POSITIONS
(CONTACTS PER ROW)
PLATING
OPERATING TEMP: -65°C TO +150°C
ALL PLATINGS ARE LEAD FREE AND HAVE .000050" NICKEL UNDERPLATE
PROCESSING TEMP: 260°C FOR 120 SECS MAX
CURRENT RATING PER CONTACT: 5 AMPS
J = PA9T/BERYLLIUM COPPER
CONTACT SURFACE
G = .000010" GOLD
Y = .000030" GOLD
TERMINATION
.000005" GOLD
.000005" GOLD
OPERATING TEMP: -65°C TO +150°C
B = .000010" GOLD
C = .000030" GOLD
**E = .000100" PURE TIN, MATTE, OVERALL
S = .000010" GOLD OVERALL
M = .000030" GOLD
.000100" PURE TIN, MATTE
.000100" PURE TIN, MATTE
PROCESSING TEMP: 260°C FOR 120 SECS MAX
CURRENT RATING PER CONTACT: 5 AMPS
F = PPS/SPINODAL (CONSULT FACTORY)
AVAILABLE IN OVERALL GOLD ONLY (S OR M PLATING CODE)
OPERATING TEMP: -65°C TO +200°C
.000010" GOLD OVERALL
** OVERALL TIN ONLY AVAILABLE ON MATERIAL CODES E, R AND G
D
D
PROCESSING TEMP: 260°C FOR 120 SECS MAX
CURRENT RATING PER CONTACT: 3 AMPS
C = PPS/BERYLLIUM NICKEL (CONSULT FACTORY)
AVAILABLE IN OVERALL GOLD ONLY (S OR M PLATING CODE)
OPERATING TEMP: -65°C TO +200°C @ 3 AMPS PER CONTACT
PROCESSING TEMP: 260°C FOR 120 SECS MAX
W = PEEK/BERYLLIUM NICKEL (CONSULT FACTORY)
AVAILABLE IN OVERALL GOLD ONLY (S OR M PLATING CODE)
OPERATING TEMP: -65°C TO +250°C
CURRENT RATING PER CONTACT: 3 AMPS
(CONSULT FACTORY FOR OTHER MATERIALS)
C
C
NOTES:
1. MATERIALS:
A. INSULATOR: SEE PART NUMBER CODING.
B. CONTACT: SEE PART NUMBER CODING.
C. PLATING: SEE PART NUMBER CODING.
2. THERMAL:
A. OPERATING TEMPERATURE: SEE PART NUMBER CODING.
B. PROCESSING TEMP: SEE PART NUMBER CODING.
C. UL FLAMMABILITY RATING: 94V-0.
3. ELECTRICAL:
B
B
A. DIELECTRIC WITHSTANDING VOLTAGE: MATED CONNECTOR MUST EXHIBIT NO EVIDENCE OF
BREAKDOWN, FLASHOVER, OR DETERIORATION FROM AN APPLIED VOLTAGE OF 950 VAC (VALUE
HAS BEEN DE-RATED), RMS 60 Hz WHEN TESTED IN ACCORDANCE WITH MIL-STD-1344, METHOD
3001. DURATION OF APPLICATION SHALL BE 5 SECS MIN.
B. INSULATION RESISTANCE (IR): 5,000 MEGOHMS @ 500 VOLTS 10% WHEN TESTED IN
ACCORDANCE WITH MIL-STD-1344, METHOD 3003 @ 25 C.
C. CONTACT RESISTANCE: 30 MILLIOHM MAX AT RATED CURRENT WHEN TESTED PER MIL-STD-202,
METHOD 307 @ 25 C 3 C.
CUSTOMER COPY
D. CURRENT RATING: SEE PART NUMBER CODING.
4. MECHANICAL:
DATE
NAME
UNLESS OTHERWISE SPECIFIED:
A. CONNECTOR IDENTIFICATION: THE PART SHALL BE MARKED WITH A LOT CODE AS A MINIMUM.
IF SPACE PERMITS ALSO MARK PART WITH SULLINS WEBSITE, AND PART NUMBER.
B. DURABILITY: 500 CYCLES MINIMUM.
DIMENSIONS ARE IN INCHES[MM]
DRAWN
2/2/2007
MV
TOLERANCES:
THE INFORMATION HEREIN CONTAINS
PROPIETARY INFORMATION OF
SULLINS ELECTRONICS AND IS NOT
TO BE REPRODUCED, USED OR
DISCLOSED TO OTHERS FOR ANY
ANGULAR: 30'
A
DESCRIPTION
.XX= .02 [.508]
A
.XXX= .005 [.1270]
EDGECARD, .156 CC, LP
Pb
.XXXX= .0005 [.0127]
SURFACE FINISH: 63 Ra
REMOVE ALL BURRS AND SHARP EDGES .010 MAX
C. BOARD THICKNESS ACCOMMODATED: .062 .008"
PURPOSE EXCEPT AS SPECIFICALLY PART NUMBER
AUTHORIZED IN WRITING BY AN
OFFICER OF SULLINS ELECTRONICS.
D. BOARD INSERTION FORCE: 16 OZ MAX PER CONTACT PAIR WHEN USING A .062" TEST BLADE.
INTERNAL INSPECTION TO BE PER SULLIN'S WORK INSTRUCTION W17.3-01.
E. BOARD WITHDRAWAL FORCE: 1 OUNCE MINIMUM PER CONTACT PAIR USING .062" PCB.
_ _M_ _DR_ _
C DWG.
SIZE
NO.
REV
E
INTERPRET DIMENSIONS AND GEOMETRIC
TOLERANCING
C10889
PER: ANSI Y14.5M-1994
RoHS COMPLIANT
SCALE: 2:1
SHEET 1 OF 3
1
4
8
7
6
5
3
2
FILE NAME: Z:\COMPONENTS\Part Assemblies\Customer Drawings\Customer Drawings for Catalog\C10889, _ _ M _ _ DR_ _ DRX,DRF,DRU,DRP PRINT: 9/23/2008