描述
Fuse

ECL055-600E 数据手册

 浏览型号ECL055-600E的Datasheet PDF文件第2页浏览型号ECL055-600E的Datasheet PDF文件第3页 
®
Bussmann  
E-Rated Medium Voltage Fuses  
For Transformer and Feeder Protection  
5.5 kV  
ECL055  
CATALOG SYMBOL: ECL055  
E-RATED MEDIUM VOLTAGE FUSES:  
Meets E requirements per ANSI C37.46  
Meets General Purpose requirements per ANSI C37.40  
FOR TRANSFORMER AND FEEDER PROTECTION  
VOLTAGE RATING: 5.5 KV  
INTERRUPTING RATING: 63KA Maximum Sym.  
CURRENT LIMITING  
CONSTRUCTION:  
• Silver element in a double concentric helical configuration  
• Silica filler  
• Silver plated copper terminals and endcaps  
• Filament wound, glass epoxy fuse tube  
AGENCY APPROVALS: UL pending.  
Electrical Characteristics  
Ampere  
# of  
Barrels  
FEATURES:  
Part Number  
Rating  
500E  
600E  
750E  
900E  
Voltage  
5kV  
IR  
Figure #  
Style  
General Purpose Fuses. Bussmanns medium voltage fuses  
provide general purpose protection and are capable of interrupt-  
ing fault currents up to 63,000A RMS sym.  
Clip-lock and bolt-in style available in double and triple  
barrel fuse designs.  
ECL055-500E  
ECL055-600E  
ECL055-750E  
ECL055-900E  
63kA  
63kA  
63kA  
63kA  
2
2
3
3
1
1
2
2
Clip-Lock  
Clip-Lock  
Bolt-In  
5kV  
5kV  
5kV  
Bolt-In  
Indoor and Outdoor Usage. The filament wound, glass epoxy  
fuse tube provides UV and moisture protection for the fuse. This  
makes Bussmanns medium voltage fuses suitable for both  
indoor and outdoor applications.  
Blown Fuse Indication. Indicator travel distance is 16mm.  
Operating Frequency: 50/60 Hz  
Part Number Construction  
Medium Voltage  
Voltage Rating  
055  
Ampere Rating  
Example  
ECL  
500E  
055 = 5.5 kV  
Time Current Curves and Dimensional Data:  
ECL055 series , see page 3.  
Peak Let-Through Curves. see page 3.  
Catalog Number Cross Reference  
Ferraz-Shawmut  
Ferraz-Shawmut  
Bussmann  
New Catalog #  
Old Catalog #  
225-007-954  
225-007-955  
A550X 750E-4  
A550X 900E-4  
Cutler-Hammer  
5HCL14-500E  
5HCL14-600E  
5HCL14-750E  
5HCL14-900E  
ECL055-500E  
ECL055-600E  
ECL055-750E  
ECL055-900E  
A055C2DORO-500E  
A055C2DORO-600E  
A055B3DORO-750E  
A055B3DORO-900E  
Current-limiting medium voltage fuses are classified into three categories:  
Full Range - defined by ANSI as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the  
minimum continuous current that causes melting of the fusible element(s), when the fuse is applied at the maximum ambient tempera-  
ture specified by the manufacturer.” It is able to interrupt any normal 60 cycle current that will melt its element.  
General Purpose - defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting cur-  
rent down to the current that causes melting of the fusible element in one hour.” Not all currents fall within this range. It is possible to  
receive an overcurrent lower than the value given by the one hour criterion.  
Back-up - defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down  
to the rated minimum interrupting current.” The minimum rated interrupting current is the lowest current that the fuse will be able to  
clear properly. This creates a need to place a low current interrupting device in series with the back-up rated fuse.  
Form No. ECL055  
4-5-00  
Page 1 of 3  
SB00020  
Rev. A  
BIF Doc. #9002  

与ECL055-600E相关器件

型号 品牌 获取价格 描述 数据表
ECL055-750E ETC

获取价格

Fuse
ECL055-900E ETC

获取价格

Fuse
ECL05US03 OMRON

获取价格

530 Watts ECL Series
ECL05US03 XPPOWER

获取价格

530 Watts ECL Series
ECL05US05 OMRON

获取价格

530 Watts ECL Series
ECL05US05 XPPOWER

获取价格

530 Watts ECL Series
ECL05US05-E XPPOWER

获取价格

Ultra Compact Size
ECL05US09 OMRON

获取价格

530 Watts ECL Series
ECL05US09 XPPOWER

获取价格

530 Watts ECL Series
ECL05US12 XPPOWER

获取价格

530 Watts ECL Series