5ꢀ30 Watts
ECL Series
xppower.com
•
•
•
•
•
•
•
Ultra Compact Size
Single, Dual & Triple Outputs
Open Frame PCB & Chassis Mount
Encapsulated PCB & Chassis Mount
<0.3 W No Load Input Power
Peak Load Capability
3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
Switching Frequency
Power Density
• 85-264 VAC (120-370 VDC)
• 47-63 Hz
• ECL05: 0.1 A rms, ECL10: 0.2 A rms
ECL15: 0.3 A rms, ECL25: 0.4 A rms
ECL30: 0.8 A rms at 230 VAC
• See tables
• 3000 VAC Input to Output
• 70 kHz typical
3
• ECL05: 2.25 W/In (PCB Mount version)
3
ECL10: 5.50 W/In (PCB Mount version)
3
Inrush Current
• 20 A at 115 VAC, 40 A at 230 VAC,
ECL15: 5.30 W/In (PCB Mount version)
cold start at 25 °C
3
ECL25: 5.ꢁ0 W/In (PCB Mount version)
3
Earth Leakage Current • Class II construction no earth
Power Factor • EN61000-3-2, class A
No Load Input Power • <0.3 W
ECL30: 7.10 W/In (PCB Mount version)
MTBF
• ECL05/10: >450 kHrs,
ECL15/25/30: >400 kHrs,
to MIL-HDBK-217F at 25 °C, GB
Input Protection
• ECL05/10: Internal T1 A/250 VAC fuse
ECL15/25/30: Internal T2 A/250 VAC fuse
Environmental
Output
Output Voltage
Output Voltage Trim
Operating Temperature • -20 °C to +70 °C, derate linearly from
• See tables
100ꢀ at +50 °C to 50ꢀ at +70 °C
•
•
5ꢀ on output 1 only, on multiple output
versions, V2 & V3 will track by same
percentage, (not ‘-E’ or ‘-S’ versions)
Cooling
Operating Humidity
• Convection-cooled
• ꢁ5ꢀ RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Initial Set Accuracy
Minimum Load
1ꢀ for output 1,
1ꢀ for output 2 of UD01 & UD02 versions,
5ꢀ for output 2 & output 3 of other versions
Operating Altitude
Vibration
• 3000 m
• 2 g, 10 Hz to 500 Hz, 10 mins/cycle,
60 mins each cycle
• Single output versions: none,
Multi output versions:
UD01 & UD02: 10ꢀ V1 & V2
UD03: 10ꢀ V1, 20ꢀ V2
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
UT02 & UT03: 10ꢀ V1, 20ꢀ V2 & V3
to meet regulation specifications
• EN55022, level B conducted & radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m 80ꢀ mod
Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, 10 Vrms Perf Criteria A
• EN61000-4-8, 10 A/m, Perf Criteria A
• EN61000-4-11, 30ꢀ for 10 ms,
60ꢀ for 100 ms, 100ꢀ for 5000 ms
Perf Criteria A, B, B
Start Up Delay
Start Up Rise Time
Hold Up Time
• 3 s max
• 14 ms max
• 16 ms typical for single output versions,
12 ms typical for multiple output versions,
at full load & 115 VAC
EFT/Burst
Surge
Line Regulation
Load Regulation
•
0.5ꢀ max for single output versions and
output 1 of multiple output versions,
0.ꢁꢀ max for output 2 & output 3 of
multiple output versions
Conducted Immunity
Magnetic Fields
Dips & Interruptions
• 1ꢀ max for single output versions,
for multiple output versions (see note 5)
Cross Regulation
Transient Response
• Multi output versions only (see note 5)
• 4ꢀ max deviation, recovery to within
1ꢀ in 500 µs for a 25ꢀ load change
Safety Approvals
• IEC60ꢁ50-1, EN60ꢁ50-1, UL60ꢁ50-1,
CSA22.2 No. 234 per cUL
Ripple & Noise
• Single output versions:
3.3-5 V versions: 50 mV pk-pk,
12-15 V versions: 120 mV pk-pk,
24-48 V versions: 200 mV pk-pk,
Multiple output versions: 1ꢀ pk-pk on any
output, 20 MHz bandwidth
Overvoltage Protection • 115-140ꢀ Vnom
Overload Protection
• Single output versions: ECL05/10/15:
120-150ꢀ, ECL25: 120-170ꢀ of total
power
Multiple output versions: 140-200ꢀ of
total power
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
• 0.05ꢀ/°C