High Voltage Ceramic Disc Capacitors (Low loss type)
High Voltage Ceramic Disc Capacitors (Low loss type)
Series:HT-KG/Char. SL/GP, 500 VDC
Series:KGE/Char. SL/GP, 1 to 3 kVDC
Series:HT-KB/Char. B/Y5P, 500 VDC
Series:KBP/Char. B/Y5P, 1 to 3 kVDC
Series:HT-KC/Char. C/Y5S, 500 VDC
Series:KRP/Char. R/Y5R 1 to 3 kVDC
n Features
n Recommended Applications
l Wide operating temperature(Ð25 to 105 ûC or Ð25
to 125 ûC)
l Snubber circuit of switching power supply
l Horizontal resonance circuitry of TV and CRT display
l Inverter type lighting apparatus
l Improved "Voltage vs.Temperature Rise "
l Ballast circuit of LCD backlighting inverter
(For series KGE)
l Other High voltage pulse and DC circuitry
l Flame-retardant insulating coating applied
l Easy mounting using Kinked Leads and Radial
Taping
n Explanation of Part Numbers
E
C
K
N
3
A
1
0
2
K
B
P
n Specifications
Characteristic
Operating
Series HT-KG and KGE
Ð25 to105 ûC
Series HT-KB, KBP, HT-KC and KRP
Series HT-KB:Ð25 to 105 ûC
Temperature Range
Rated Voltage
Series KBP, HT-KC and KRP:Ð25 to 125 ûC
500VDC to 3 kVDC
500 VDC to 3 kVDC
Dielectric
Withstanding
Voltage
Rated Voltage 500VDC:1250 VDC for 1 to 5 seconds
Rated Voltage 1 to 3 kVDC:
Rated Voltage 500VDC:1500 VDC
for 1 to 5 seconds
200 % of Rated Voltage for 1 to 5 seconds
Rated Voltage 1 to 3 kVDC:
200 % of Rated Voltage
for 1 to 5 seconds
Within the specified tolerance,
Within the specified tolerance,
when measured at 1 MHz ± 20 %,
1 to 5 Vrms, and 20 ûC
Capacitance
when measured at 1 kHz ± 20 %,1 to 5 Vrms, and 20 ûC
30 pF or under Q > 400+20 C
Series HT-KB and KBP:tand > 0.025
(C:Cap.pF)
Series HT-KC
Series KRP
:tand > 0.003
:tand > 0.002
Q or
Dissipation Factor
over 30 pF Q > 1000
at 1 MHz ± 20 %,1 to 5 Vrms.
and 20 ûC
(tand)
at 1 kHz ± 20 %,1 to 5 Vrms. and 20 ûC
Insulation
10000 M W min.
Resistance
at 500 VDC 1 minute electrification
Series Temp.Char max.Cap.Change Temp. Range
Temperature Coefficient:
+350 to Ð1000 ppm/ûC
HT-KB
KBP
B/Y5P
B/Y5P
C/Y5S
R/Y5R
±10 %
±10 %
±20 %
±15 %
Ð25 to 85 ûC
Ð25 to 85 ûC
Ð25 to 85 ûC
Ð25 to 85 ûC
Temperature
Characteristics
(Temperature Range:20 to 85ûC)
HT-KC
KRP
n Handling Precautions
n Packaging Information
See Pages 80 to 81
See Pages 82 to 83
Rev.02/04