4
1
8
7
5
3
2
6
REVISIONS
REV.
B
ECO. NO
1886
DESCRIPTION
DATE
BY
ADD PG TERMINATION. UPDATE CONTACT POINTS
BASED ON CHANGES TO PIN
1/7/2009
MNH
F
E
D
B
A
UPDATE PCB LAYOUT, REF DIM FOR CONTACT
POINT LOCATION, DWG VIEW TO SHOW RIB ON
INSULATOR BOTTOM, ADD CONTACT GAP DIM,
TOL FOR INSULATOR WIDTH & 1ST RAB DIM .075,
REMOVE PP TAIL OPTION VIEW (CONSULT
FACTORY)
F
C
2696
10/29/2012
JH
.025 0.64
.100 2.54
2X .125 3.18
.075 1.91
SEE NOTE 13
+.005
-.015
+0.13
10.16
.400
E
E
-0.38
.030 0.76
.030 0.77
C
POINT OF
CONTACT
A
A
.180 4.57
.560 14.22
.425 10.80
INSERTION DEPTH
.075±.010 1.91±0.25
.105 2.68
.345 8.77
.250 6.35
POINT OF
CONTACT
.150 3.81
D
D
F
PB = .100 .025[2.54 0.64]
PG = .140 .025[3.56 0.64]
PE = .180 .025[4.57] 0.64]
PU = .250 .025[6.35 0.64]
PJ = .500 .025[12.70 0.64]
(OTHER LENGTHS AVAILABLE, CONTACT FACTORY)
SEE NOTE 16
_ _C_ _D_ _H
C
C
D
2X .125 3.18
FOR (S) MOUNTING
A
.100 2.54
.330 8.38
.150 3.81
.043 1.09 MIN
PC BOARD LAYOUT RECOMMENDED
B
B
NOTES:
1. INSULATOR MATERIAL: SEE PART NUMBER CODING
2. CONTACT MATERIAL: SEE PART NUMBER CODING
3. PLATING: SEE PART NUMBER CODING
4. OPERATING TEMPERATURE: SEE PART NUMBER CODING
5. PROCESSING TEMP: SEE PART NUMBER CODING
6. UL FLAMMABILITY RATING: 94V-0
7. OPERATING VOLTAGE: 700 VAC MINIMUM AT SEA LEVEL
8. CURRENT RATING: 3 AMP
CUSTOMER COPY
9. CONTACT RESISTANCE: 30 MILLI OHMS MAX
10. INSULATION RESISTANCE: 5000 MEGA OHMS
11. DURABILITY: 500 CYCLES MIN
DRAWN DATE NAME
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES [MM]
10/29/12 JH
THE INFORMATION HEREIN CONTAINS
PROPIETARY INFORMATION OF
TOLERANCES:
A
TITLE
A
12. CONNECTOR IDENTIFICATION: THE PART SHALL BE MARKED WITH A PART NUMBER AND LOT CODE
13. BOARD THICKNESS ACCOMMODATED: .062 .008[1.57 0.20]
SULLINS ELECTRONICS AND IS NOT
TO BE REPRODUCED, USED OR
DISCLOSED TO OTHERS FOR ANY
PURPOSE EXCEPT AS SPECIFICALLY
AUTHORIZED IN WRITING BY AN
OFFICER OF SULLINS ELECTRONICS.
EDGECARD, .100 CC HP
ANGULAR:
DECIMALS
1
Pb
PART NUMBER
14. INSERTION FORCE: 16 OZ MAX PER CONTACT PAIR WHEN USING A .062[1.57] TEST BLADE
INTERNAL INSPECTION TO BE PER SULLIN'S WORK INSTRUCTION WI7.3-01
_ _C_ _D_ _ _, (PB,PE,PG,PJ,PU,PP)
.XX= .02 [.5]
.XXX= .005 [.13]
.XXXX= .0005 [.013]
SIZE
CAGE CODE DWG. NO.
REV
15. WITHDRAWAL FORCE: 1 OZ MIN PER CONTACT PAIR USING .062[1.57] PCB
C
54453
C11116
C
R
oHS COMPLIANT
16. NUMBER OF GROOVES AND LENGTH VARY WITH NUMBER OF POSITIONS. 70-POSITION HAS NO GROOVE.
SCALE: 2:1
SHEET 1 OF 3
1
4
8
7
6
5
3
2
FILE NAME: C11116, _ _C_ _D_ _ _(PB,PE,PG,PJ,PP,PU]