Ordering information
Small,High-voltage pulses common mode EMI/EMC Filters (1-Stage filter)
EAP -10 -472 -O
EAP series
1
2
3
4
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
R
table1.1 Line to ground capacitor code
Line to ground
Leakage Current
Code
capacitor
(nominal value)
Not Provided
100pF
(Input 125/250V 60Hz)
A/ 10 A max
12.5 A/ 25 A max
25 A/ 50 A max
37.5 A/ 75 A max
50 A/100 A max
000
101
221
331
471
681
102
222
332
472
5
220pF
330pF
470pF
75.5 A/150 A max
0.13mA/0.25mA max
0.25mA/0.5 mA max
0.38mA/0.75mA max
0.5 mA/1.0 mA max
680pF
1000pF
2200pF
3300pF
4700pF
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
*
The terminal cover is retracted inside the unit
DIN rail installation type is option
4Options
D:DIN rail installation type
The dimensions change when the option is set.
Refer to External view.
*
Features of EAP series
Small,High-voltage pulses common mode EMI/EMC Filters(1-Stage filter)
-Single Phase 250 VAC
-Small-size
-Quick and easy push-down terminal
Just connect the wires,push-down and tighten
the screws with a screwdriver
Specifications
No.
Items
EAP-03-472
EAP-06-472
EAP-10-472
EAP-16-472
EAP-20-472
EAP-30-472
1
Rated Voltage[V]
AC 1f250 / DC250
2
Rated Current[A]
3
6
10
16
20
30
3
Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4
Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MWmin at room temperature and humidity
5
Leakage current 125/250V 60Hz
DC resistance
0.5mA/1.0mA max
180mWmax 110mWmax
6
40mWmax
20mWmax
10mWmax
6mWmax
7
Safety agency approval temperatures
Operating temperature
Operating humidity
-25 to +85C(Refer to Derating Curve)
-40 to +85C(Refer to Derating Curve)
20 to 95%RH (Non condensing)
8
9
10
11
12
13
14
Storage temperature/humidity
Vibration
-40 to +85C/20 to 95%RH (Non condensing)
2
10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis
2
Impact
196.1m/s (20G), 11ms Once each X, Y and Z axis
Safety agency approvals
Case size (without projection) /Weight
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view)
Circuit Diagram
Derating Curve
Case
100
80
3
1
60
CY
CY
LINE
LOAD
40
4
2
20
0
-40
-30
-20
40
50 55 60
70
80
90
Ambient Temperature [C]
: Mounting Plate
CY : Line to ground capacitor