DIN Rail Mount
DataSheet
DRC Series with
EMR Auxiliary Contacts
Start / Stop Reversing
• 7.6 Amp AC Semiconductor Motor Controller
• Load voltage range up to 600 VAC
• Fits standard 35mm DIN Rail
• LED input status indicator
• AC or DC control
• Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
•
C-UL-US Listed, IEC Rated, CE & RoHS Compliant, Horsepower Rated
• Built-in Overvoltage Protection
• Ultra-efficient thermal management design (Patented)
See DRC Series models with Solid State Auxiliary Contacts
Solicon DRC Series with EMR Auxiliary Contacts are Solid State instantaneously upon application of the control voltage unless an
Contactors intended for frequently switching on and off three instantaneous change of direction is commanded, then it will
phase loads up to 5 HP, 600 VAC 7.6 Amps. They are available in delay the direction change by 100msec in order to prevent
both contactor versions DRC3P and reversing contactor versions simultaneous forward and reverse operations.
DRC3R.
All the models of Solicon DRC Series with EMR Auxiliary Contacts
The Solicon Contactor DRC3P is available in either instantaneous combine the benefits and advantages of a solid state contactor
turn-on (for Motor Control) or zero voltage turn-on (for Resistive with the functionality and simplicity of use of an
Loads). It is available in either 2 or 3 controlled leg versions. The electromechanical contactor thanks to the proprietary thermal
2 legs control version is particularly suitable for motor control management technology (Patented) and complete electrical
circuits where the neutral conductor is not utilized.
insulation (no grounding required); the embedded EMR auxiliary
contacts, normally open and/or normally closed, are intended to
be used at 110VDC/140VAC. All models include overvoltage
protection.
The Solicon Reversing Contactor DRC3R includes an interlock
control that allows only off, forward and reverse operation in a
safe mode while providing high space saving; it switches
PRODUCT SELECTION
Control Voltage
24 VAC/DC
1 NO + 1NC Auxiliary Contact
2 NO Auxiliary Contact
DRC3P48D440, DRC3P60D440
DRC3R40E440, DRC3R48E440
DRC3P48D433, DRC3P60D433
24 VDC
AVAILABLE OPTIONS
Operating Voltage
40: 400 VAC
Load Current per Phase
4: 7.6 Amp FLA
(3R function only)
48: 480 VAC
60: 600 VAC
(x2 Controlled Legs
& 3R function);
4.8 Amp FLA
Switching Mode
(3P function only)
Blank: Zero Voltage Turn-On
(3P function only)
Series
(x3 Controlled Legs only) R: Instantaneous Turn-On
4
DRC 3P 48
D
33
R
2
Function
Control Voltage
D: 18-30 VAC/DC
(3P function only)
E: 18-30 VDC
Auxiliary Contacts,
N.O. - N.C.
Controlled Legs
(3P function only)
3P: Contactor
3R: Reversing Contactor
33: 1 Normally Open EMR ; Blank: 3 Controlled Legs
1 Normally Closed EMR 2: 2 Controlled Legs
(3P function only)
(3R function only)
40: 2 Normally Open EMR
Required for valid part number
For options only and not required for valid part number
FDE-07-01 REV. A
Do not forget to visit us at: www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.