5秒后页面跳转
DRA3P48C4R2 PDF预览

DRA3P48C4R2

更新时间: 2024-11-25 22:59:47
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
5页 684K
描述
RELAY SSR 480 V

DRA3P48C4R2 数据手册

 浏览型号DRA3P48C4R2的Datasheet PDF文件第2页浏览型号DRA3P48C4R2的Datasheet PDF文件第3页浏览型号DRA3P48C4R2的Datasheet PDF文件第4页浏览型号DRA3P48C4R2的Datasheet PDF文件第5页 
DIN Rail Mount Contactor  
Datasheet  
DRA3P Series  
2.4 & 4.2 Amp rated Solid State Contactor  
Load voltage range of 48-510 VAC, 3-Phase  
Fits standard 35mm DIN-RAIL  
LED input status indicator  
AC or DC control  
Zero-crossing (resistive loads) or instantaneous turn-on (inductive loads) output  
cUL Recognized, IEC Rated, CE & RoHS Compliant, Horsepower Rated  
Built in Overvoltage Protection  
Start / Stop  
PRODUCT SELECTION  
Control Voltage  
4-6 VDC Control  
18-28 VDC Control  
36-60 VAC Control  
90-140 VAC Control  
200-265 VAC Control  
2.4 A  
4.2 A  
DRA3P48D2  
DRA3P48E2  
DRA3P48C2  
DRA3P48B2  
DRA3P48A2  
DRA3P48D4  
DRA3P48E4  
DRA3P48C4  
DRA3P48B4  
DRA3P48A4  
AVAILABLE OPTIONS  
Rated Load Current  
2: 2.4 Amp/  
1HP @ 480 VAC  
4: 4.2 Amp/  
Controlled Legs  
Blank: 3 Legs  
2: 2 Legs  
Operating Voltage  
48: 48-510 VAC  
2HP @ 480 VAC  
Series  
DRA 3P 48  
D
4
R
2
Function  
Control Voltage  
Switching Type  
3P: 3 Phase  
D: 4-6 VDC  
Blank: Zero Voltage Turn-On  
R: Instantaneous Turn-On  
E: 18-28 VDC  
A: 200-265 VAC  
B: 90-140 VAC  
C: 36-60 VAC  
Required for valid part number  
For options only and not required for valid part number  
OUTPUT SPECIFICATIONS AC Output (1)  
Description  
Operating Voltage (47-63Hz) [Vrms]  
2.4 A  
48-510  
480  
4.2 A  
48-510  
480  
Rated Operating Voltage (Vrms)  
Transient Overvoltage [Vpk] (2)  
1200  
2.4/2.4  
2.1/2.1  
0.15  
1200  
4.2/2.4  
3.4/2.1  
0.15  
Maximum Resistive Load Current UL/AC51 [Arms] (3, 8)  
Maximum Motor Load Current UL/AC53 [Arms] (3, 4)  
Minimum Load Current [Arms]  
Maximum Off-State Leakage Current @ Rated Voltage [mArms]  
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]  
Maximum On-State Voltage Drop @ Rated Current [Vrms]  
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]  
Maximum I²t for Fusing (50/60 HZ, 1/2 cycle) [A² sec]  
1.0  
500  
1.0  
500  
1.15 per Channel  
285/300  
410/375  
0.5/0.37  
1.0/0.75  
1.0/0.75  
0.5  
24/10  
0.5-4.0  
12.0 in lb (1.36 Nm)  
1.15 per Channel  
285/300  
410/375  
0.75/0.37  
1.5/0.75  
2.0/0.75  
0.5  
(5)  
(6)  
(7)  
HP/IEC 60947 Rating @ 240V, 40°C [HP/KW]  
HP/IEC 60947 Rating @ 380V, 40°C [HP/KW]  
HP/IEC 60947 Rating @ 480V, 40°C [HP/KW]  
Minimum Power Factor (with Maximum Load)  
Min/Max stranded/solid wire [AWG]  
Min/Max stranded/solid wire [IEC mm²]  
Load Terminal Screw Torque Range:  
24/10  
0.5-4.0  
12.0 in lb (1.36 Nm)  
FDE-07-01 REV. A  
Do not forget to visit us at: www.crydom.com  
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.  

与DRA3P48C4R2相关器件

型号 品牌 获取价格 描述 数据表
DRA3P48D2 CRYDOM

获取价格

DIN rail mount
DRA3P48D22 ETC

获取价格

RELAY SSR 480 V
DRA3P48D2R2 ETC

获取价格

RELAY SSR 480 V
DRA3P48D4 CRYDOM

获取价格

DIN rail mount
DRA3P48D42 ETC

获取价格

RELAY SSR 480 V
DRA3P48D4R ETC

获取价格

RELAY CONTACT 3PH 480VAC 4A 5V
DRA3P48E2 CRYDOM

获取价格

DIN rail mount
DRA3P48E22 ETC

获取价格

RELAY SSR 480 V
DRA3P48E2R ETC

获取价格

RELAY CONT 3PH 480VAC 2A 24VDC
DRA3P48E2R2 ETC

获取价格

RELAY SSR 480 V