Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 55KHz
3 years warranty
SPECIFICATION
MODEL
DR-120-12
DR-120-24
DR-120-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
10A
5A
2.5A
0 ~ 10A
120W
0 ~ 5A
0 ~ 2.5A
120W
100mVp-p
48 ~ 53V
1.0%
120W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
80mVp-p
OUTPUT
12 ~ 14V
24 ~ 28V
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
0.5%
1.0%
0.5%
1.0%
1.0%
500ms, 70ms/230VAC
500ms, 70ms/115VAC at full load
36ms/230VAC
32ms/115VAC at full load
88 ~ 132VAC/176 ~ 264VAC by switch
248 ~ 370VDC
84%
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
47 ~ 63Hz
80%
85%
INPUT
2.6A/115VAC
1.6A/230VAC
COLD START 20A/115VAC
<3.5mA / 240VAC
40A/230VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
29 ~ 33V 58 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
90 (TSW1) 5 (TSW1)
15 ~ 16.5V
PROTECTION OVER VOLTAGE
5
90
85
5
(TSW1)
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508, UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
Compliance to EN55011,EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
136.8Khrs min. MIL-HDBK-217F (25
65.5*125.2*100mm (W*H*D)
)
OTHERS
NOTE
DIMENSION
0.79Kg; 20pcs/16.5Kg/1.29CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:DR-120-SPEC 2008-04-07