• Low Cost
• 12V, 24V or 48V Outputs
• Wide Range 340 to 575VAC Input
• Parallel Function Switch (240 & 480W)
• Current Share (960W)
• -40°C to +71°C Operation
• Convection Cooled
Key Market Segments & Applications
Industrial Controls:
Factory Automation:
Test & Measurement:
Motor Control Systems
Process Control, Automotive,
Chemical Processing
Burn in & Test,
Instrumentation Measurement
DPP120 - 960 Series
120W, 240W, 480W & 960W 3 Phase
DIN Rail Mount Power Supplies
DPP120 - 960 Features and Benefits
Features
Benefits
• PFC Compliant to EN61000-3-2
• UL508 Approvals
• Supports Global Use
• Easier System Configuration
• Easy System Integration
• TS35/7.5 or TS35/15 DIN Rail Mounting
Specifications
MODELS
DPP120-xx-3
DPP240-xx-3
DPP480-xx-3
DPP960-xx-3
ITEMS
AC Input Voltage range
Input Frequency
(1)
VAC
340 - 575VAC, three phase
Hz
47 - 63Hz
Inrush Current (380-480VAC) (typ)
Power Factor
A
10A
0.55
0.36A
20A
0.55
20A
0.65
1.1A
30A
0.8
1.72A
(2)
-
Input Current (400VAC) (typ)
Output Voltage Accuracy
Line Regulation
A
0.65A
%
-0, +1% of Nominal
1%
%
Load Regulation
%
1%
1% ( 5% when set in parallel mode)
Ripple and Noise (20MHz BW)
Overcurrent Protection (Typ)
Overvoltage Protection
Overtemperature Protection
Hold Up Time (380-480VAC)
Parallel operation (up to 90% load)
LED Indicators
DC Good Relay (24V models only)
Operating Temperature
Storage Temperature
Operating Humidity (non condensing)
Cooling
mV
100mV
100mV
120 - 140%
100mV
110 - 135%
80mV
110 - 130%
-
115 - 135%
V
See model selector
Yes, auto recovery
> 20ms > 20ms
Set in parallel (droop) mode - up to 2 units
Green LED = On, Red LED = DC Output Low
-
ms
> 20ms
-
> 15ms
-
-
-
0.3A rated normally open relay contacts, closes when output is above 17.6 - 19.4V
-40°C(3) to +71°C (Derate linearly 2.5%/°C from 61°C to 71°C, 3.5%/°C for DPP960)
-40°C to +85°C
-
-
-
20 - 95% RH
-
Convection. Recommend 25mm clearance on all sides
Input to Output 3kVAC, Input to Ground 1.5kVAC for 1 min.
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
IEC 60068-2-6. 10- 500Hz, 2G on X, Y & Z axes
IEC 60068-2-27. Half sinewave, 4G, 22ms, 3 times each face
UL508 Listed, UL60950-1, EN60950-1, CE
Withstand Voltage
-
Isolation Resistance
Vibration
Ω
-
Shock
-
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
-
-
EN55022 class B
IEC 61000-4-2, -3, 4, -5, -6. -8, -11
-
Weight (Typ)
g
800
74.3 x 124 x 111.9
70
1100
89 x 124 x 111.9
25
1720
150 x 124 x 111.9
80
3400g
275.8 x 126.2 x 111.9
52
Size (WxHxD)
mm
kHz
Switching Frequency
MTBF (Bellcore Issue 6 @ 40°C, GB) Hours
527,000
488,000
411,000
352,000
Case material
Warranty
-
Metal
3
yrs
1
DPP120 - 960 Series