5-60 Watts
xppower.com
DNR05-60 Series
•
•
•
•
•
•
•
Rugged Design for Industrial Applications
Up to 89% Efficiency
Wide Adjustment Range
DC OK 24 V Models
DC Standby Versions
Connector Options
Full Power to +60 ˚C
Specification
Input
General
Input Voltage
• 90-264 VAC, 120-370 VDC: DNR05/10/18
85-264 VAC, 90-375 VDC: DNR30/60
Efficiency
Isolation
• See tables
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Input Frequency
Inrush Current
• 47-63 Hz
• 5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Switching Frequency
Signals
• 100 KHz typical
• DC ON indicator LED Green: All models
DC LOW indicator LED Red:
5-18 W models
Power Factor
• Meets EN61000-3-2 for class A equipment
Earth Leakage Current • 0.8 mA max
DC OK: 24 V 30-60 W models
MTBF
• 200 kHrs typical per MIL-HDBK-217F
GF, +40 ºC
Output
Output Voltage
• See tables
• See tables
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Environmental
•
1ꢀ
Operating Temperature • -10 °C to +70 °C, derate linearly from
+50 °C for 5 & 18 W models, +60 °C for
• No minimum load required
• <1000 ms
Start Up Delay
all other models (See derating curves)
Start Up Rise Time
Hold Up Time
• <150 ms
Cooling
• Convection-cooled
• 5 W: 30/130 ms at 115/230 VAC
10 W: 25/100 ms at 115/230 VAC
18 W: 20/75 ms at 115/230 VAC
30 W: 20/30 ms at 115/230 VAC
60 W: 20/30 ms at 115/230 VAC
Operating Humidity
Storage Temperature
Shock
• 20-95ꢀ RH, non-condensing
• -25 ºC to +85 ºC
• 4 g, 22 ms, X, Y & Z axis
• 1 g, 10 Hz to 500 kHz, along X, Y & Z axis
Vibration
Line Regulation
Load Regulation
• 5-18 W: 1.0ꢀ max
30-60 W: 0.5ꢀ max
EMC & Safety
Emissions
• EN55022, level B conducted
• 5-18 W: 2.0ꢀ max
30-60 W: 0.5ꢀ max
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2, class A
Transient Response
Ripple & Noise
• 300 µs for a 50ꢀ load change
• 50 mV pk-pk, 20 MHz BW
• EN61000-3-3 amendments 1 & 2
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
Overvoltage Protection • Output clamps at 120-145ꢀ Vnom
Overload Protection • 105-145ꢀ
Short Circuit Protection • 5-18 W: Trip and restart (Hiccup mode)
Surge
30-60 W: Constant power
Dips & Interruptions
• EN61000-4-11, 30ꢀ 10 ms,
60ꢀ 100 ms, 100ꢀ 5000 ms
Perf Criteria A, B, B
Temperature
Coefficient
•
0.03ꢀ/ºC
Safety Approvals
• EN60950-1:2001, UL508,
UL1310 - see note 3 & ratings table,
UL60950-1, cUL60950-1, CE Mark