Features
•
•
•
•
•
•
•
High power density
High efficiency
Remote voltage sense & remote operation
Master/slave paralleling, active current sharing
Low output noise
CE mark, UL listing mark and C-UL listing mark
Ethernet/LAN Interface Option
OPERATING
Specifications
INPUT
Input voltage
Efficiency
84% typical at maximum power
82% typical for DLM 5-7 and DLM 8-75
90-132 / 180-264VAC,auto-ranging, 2 Wires +
ground
Parallel/Series operation
Up to 4 unit of the same model can be connected
in parallel, with active current sharing control.
Series operation, multiple units of same model can
be connected in series, limited by 300Vpk between
either output terminal and chassis
Frequency
47-63Hz
Current
11A max. at 115VAC, 6A max. at 230VAC
OUTPUT
Voltage adjustment
Current adjustment
Zero to rated output
Zero to rated output
See table
Remote sense
The maximum allowed load line drop with remote
sensing is 1V total for DLM 5-75 & DLM 8-75
model, 2V total for all other model
Ripple & Noise
Line regulation
Remote programming
Voltage , current (0-100%) and OVP (5-110%) of
full scale can be programmed by selectable
0-5VDC, 0-10VDC, or 0-5KΩ
Voltage: 0.005% of Vmax + 2mV
Current: 0.01% of Imax + 2mA
Load regulation
Voltage: 0.005% of Vmax + 2mV
Current: 0.02% of Imax + 5mA
Remote monitoring
Voltage or current can be Monitored with user-
selectable ranges, scaled to 0-5VDC or 0-10VDC
Transient response
500s to steady-state output voltage
(within 0.1% of Vmax) for 50-100% or 100-50%
load change
Displays and indicators
Two 3.5 digital LED displays indicate voltage,
current and, over-voltage output set point, fault,
external off, remote and output on
Stability
+/-0.05% of maximum voltage or current over 8
hours after 30 minute warm-up time at fixed line,
load and temperature
Software
LabVIEW® driver for M9G/M85
(Contact Powerbox)
Regulatory compliance
CE mark, UL listing mark and
C-UL listing mark
0.02%/°C of maximum output voltage
0.03%/°C of maximum output current
Temperature coefficient
MECHANICAL
ENVIRONMENTAL
Case
Enclosed
Operating temperature
0°C to 50°
Dimensions
1RU 44(H) x 216 (W) x 432mm(D)
4.4Kg
Storage temperature
Cooling
-40°C to 65°C
Weight
Internal variable speed fan with over-temperature
protection.
Connectors
Input: IEC320
Output: Bus bar with 10-32 screws for 5-60VDC
models; terminal blocks with 6-32 screws for
80-300V models
481