70-150 Watts
xppower.com
DLG-HV Series
•
•
•
•
•
•
•
AC Input LED Driver
Constant Current Operation
High Power Factor
High Efficiency
Water Proof to IP67
90-305 VAC Input Voltage Range
3 Year Warranty
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-305 VAC, see derating curve
• 47-63 Hz
• 70 W: 1.2 A at 115VAC, 0.6 A at 230VAC,
100 W: 1.4 A at 115VAC, 0.7 A at 230VAC,
150 W: 2.0 A at 115VAC, 1.0 A at 230VAC
• 65 A at 230 VAC, cold start +25 °C
• >0.94 at 230 VAC, full load
Efficiency
Isolation
• See table
• 3750 VAC Input to Output
1880 VAC Input to Ground
500 VAC Output to Ground
• DLG50/70: 40-80 kHz
DLG100/150: PWM 60-80 kHz,
PFC 55-133 kHz
Switching Frequency
Inrush Current
Power Factor
MTBF
• >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Earth Leakage Current • 750 µA max at 230 VAC
Input Protection
• DLG70/100 T2.0A/300V fuse fitted in line,
DLG150 T3.5A/300V fuse fitted in line
Environmental
Operating Temperature • -30 °C to +70 °C (see derating curve)
Operating Humidity
Storage Temperature
Operating Altitude
Vibration
• 5-100% RH, non-condensing
• -40 °C to +80 °C
• 3000 m
• 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
Output
Output Voltage
• See table
• No minimum load required
• 2 s max at 240 VAC
Minimum Load
Start Up Delay
Line Regulation
Load Regulation
Turn On Overshoot
Transient Response
•
•
0.5%
5.0% of nominal output current
EMC & Safety
• 5% max
Emissions
• EN55015, class B conducted and radiated
• EN61000-3-2, class A
EN61000-3-2, class C for loads >80%
• EN61000-3-3
• EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria B
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, installation class 3,
Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria A
• 5% maximum deviation, recovery to within
1% in 10 ms for a 50% load change
• DLG70: 700 mV
DLG100: 1000 mV
DLG150: 2000 mV (see note 2)
Harmonic Currents
Ripple & Noise
Voltage Flicker
ESD Immunity
Overvoltage Protection • 110-142%, recycle mains to reset
Overtemperature
Protection
Radiated Immunity
EFT/Burst
• Unit shuts down, recycle mains to reset
Surge
Overload Protection
• 105% maximum, auto recovery
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
Conducted Immunity
Dips & Interruptions
• 0.04%/°C
• EN61547, >95% 10 ms, 30% 200 ms, Perf
Criteria B, B for 70/100 W, A, A for 150 W
Safety Approvals
• EN61347, UL8750, CE Mark