Document 149-1
Through Hole Data Line EMI Filters
Thesefiltersaredesignedtovirtuallyeliminateconducted
EMI in data line applications. They provide exceptional
common mode noise reduction from 5 MHz to 300 MHz
whilepassingsignallinedatafrequenciesbelow200MHz
with minimal attenuation.
These low resistance filters feature excellent electrical
isolation, environmental stability and low cost. Optional
covers make them auto insertable. They also meet IEC
695-2-2 needle flame test requirements.There are 8, 4,
3 and 2-line versions with DC current capacity of 100 mA
(DLF x000 series) or 500 mA (DLF x500 series).
Coilcraft Designer’s Kit D303 contains four samples of
all values shown plus samples of our PDLF and CCDLF
surface mount filters. To order, contact Coilcraft or visit
http://order.coilcraft.com.
Current
DCR
max
Part
number
max L/winding
Isolation
Lines (mA)
(µH)
(mOhms) (Vrms)
Part number
DLF 2000L
DLF 2000CL
DLF 2500L
DLF 2500CL
DLF 3000L
DLF 3000CL
DLF 3500L
DLF 4000L
DLF 4500L
DLF 8000L
DLF 8000CL
DLF 8500L
DLF 8500CL
Weight typ (g)
0.74
Packaging
74 per tube
64 per tube
74 per tube
64 per tube
74 per tube
64 per tube
74 per tube
55 per tube
55 per tube
27 per tube
27 per tube
25 per tube
25 per tube
DLF 8000L1
DLF 8500L1
DLF 4000L
DLF 4500L
DLF 3000L1
DLF 3500L
DLF 2000L1
DLF 2500L1
8
8
4
4
3
3
2
2
100
500
100
500
100
500
100
500
28
25
28
24
28
24
28
24
100
45
100
45
100
45
100
45
300
300
300
300
300
300
300
300
1.32
0.78
1.36
0.83
1.41
0.91
0.95
1.09
1. For optional cover add “C” to part number just before the “L”: e.g.
DLF 8500CL. Not available on 3500, 4000 and 4500 parts.
2. Operating temperature range –40°C to +85°C.
3. Electrical specifications at 25°C.
1.56
2.70
2.22
3.36
Typical Response (Measured on an HP 8753D network analyzer. Ref: 50 Ohms)
Terminations Tin-silver over tin over phos bronze
0
Differential Mode
10
20
30
0.1
1
10
100
1000
Frequency (MHz)
Document 149-1 Revised 07/02/12
US +1-847-639-6400 sales@coilcraft.com
UK +44-1236-730595 sales@coilcraft-europe.com
Taiwan +886-2-2264 3646 sales@coilcraft.com.tw
China +86-21-6218 8074 sales@coilcraft.com.cn
Singapore + 65-6484 8412 sales@coilcraft.com.sg
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.